- Which refrigerant has been phased out due to ozone depletion
potential?
A. R-410A
B. R-22
- R-134a
D. R-32
R-22 has a high ozone depletion potential and is being phased out under the Montreal Protocol.
- The minimum efficiency rating for new central air conditioners in
Florida is measured in:
A. EER
B. SEER
C. COP
D. SEER
SEER (Seasonal Energy Efficiency Ratio) measures cooling efficiency over a typical season.
- Which type of system uses water as the primary heat transfer medium?
- Packaged unit
- Chilled water system
- Heat pump
- Split system
Chilled water systems circulate water to transfer heat in large commercial HVAC installations. 1 / 3
4. The primary purpose of a TXV (Thermostatic Expansion Valve) is to:
- Compress refrigerant
- Regulate refrigerant flow into the evaporator
- Filter impurities
- Condense refrigerant
- Which of the following is considered a high-efficiency air conditioner?
TXVs control the flow of refrigerant based on superheat to optimize evaporator performance.
A. 10 SEER
B. 12 SEER
C. 15 SEER
D. 13 SEER
Units with SEER ratings of 14–16 or higher are generally considered high-efficiency for residential use.
6. In Florida, contractors must be licensed by:
A. OSHA
B. EPA
- Florida Department of Business and Professional Regulation
(DBPR)
D. AHRI
The DBPR regulates licensing for air conditioning contractors in Florida.
- What is the main cause of low refrigerant pressure in a system?
- Dirty filter
- Oversized unit
- Leak in the system
- Excessive insulation
Low pressure often indicates a refrigerant leak, which must be located and repaired.
8. The term "superheat" refers to:
- Temperature below evaporator saturation
- Pressure above condenser saturation
- Temperature above the boiling point of refrigerant at a given
- The same as subcooling
pressure
Superheat measures how much the refrigerant vapor has been heated beyond its saturation temperature. 2 / 3
9. A split system air conditioner separates:
- Compressor and thermostat
- Evaporator coil and condenser unit
- Ductwork and filter
- Furnace and humidifier
- Which refrigerant is considered environmentally friendly with
Split systems have the condenser outdoors and the evaporator coil indoors.
zero ozone depletion?
A. R-22
B. R-410A
C. R-12
D. R-502
R-410A does not deplete the ozone layer and is widely used in new systems.
- What is the function of the condenser coil?
- Absorb heat from indoor air
- Release heat to the outdoor environment
- Pump refrigerant
- Remove moisture from air
The condenser coil transfers heat from the refrigerant to the outside air.
12. If a system is short-cycling, this indicates:
- Proper operation
- Oversized equipment or refrigerant issues
- Correct thermostat calibration
- Low humidity
- What is the primary safety device to prevent compressor damage
Short cycling often results from oversized units, low refrigerant, or control issues.
from high pressure?
A. TXV
- Thermostat
- High-pressure switch
- Expansion valve