Class notes Jan 3, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

Florida Certified Electrical Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf

  • Florida Electrical Contractor licensing is regulated by which
  • authority?

  • Florida Department of Labor
  • Florida Electrical Board
  • Florida Department of Business and Professional Regulation (DBPR)
  • Florida Construction Licensing Bureau

Rationale: DBPR manages licensing and enforcement for all certified

contracting professions.

2. The NEC is primarily concerned with:

  • Utility provider design standards
  • Safety of electrical installations
  • Design aesthetics
  • Energy efficiency standards only

Rationale: NEC’s core purpose is practical safeguarding of persons and

property.

  • What is the minimum size grounding electrode conductor for a 200-
  • amp service using copper? 1 / 3

A. 4 AWG

B. 6 AWG

C. 2 AWG

D. 8 AWG

Rationale: NEC Table 250.66 specifies 6 AWG copper for 2/0 service

conductors (200A).

  • Which conductor is permitted to be smaller than the ungrounded
  • conductors?

  • Service entrance conductors
  • Equipment grounding conductor
  • Feeder conductors
  • Branch circuit conductors

Rationale: Equipment grounding conductors may be reduced per NEC

250.122.

  • The minimum burial depth for rigid metal conduit under a driveway

is:

  • 6 inches
  • 12 inches
  • 18 inches
  • 24 inches

Rationale: NEC Table 300.5 requires 18 inches for rigid metal under

driveways.

  • Maximum number of disconnects allowed in one service disconnect
  • grouping?

  • 4
  • 5

C. 6 2 / 3

  • 8

Rationale: The “six-disconnect rule” applies per NEC 230.71.

  • The ampacity of a conductor must be corrected when ambient

temperature exceeds:

A. 30°C (86°F)

B. 40°C (104°F)

C. 25°C (77°F)

D. 35°C (95°F)

Rationale: NEC ampacity tables assume 30°C; above this, correction

factors apply.

8. A GFCI device trips when current imbalance exceeds:

  • 3 mA
  • 2 mA
  • 5 mA
  • 15 mA

Rationale: Standard personnel-protection GFCIs trip at 4–6 mA.

  • Which wiring method is allowed in a plenum ceiling?
  • NM cable
  • Plenum-rated cable (CMP)
  • UF cable
  • Standard THHN in no raceway

Rationale: Only plenum-rated assemblies approved for air-handling spaces

are allowed.

  • Minimum working clearance in front of 480V electrical gear?
  • / 3

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

This document featured in-depth analysis that was incredibly useful for my research. Such an excellent resource!

Download Document