Exam Questions And Correct Answers

Class notes Jan 3, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

Florida Certified Master Electrician Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf

  • What is the minimum size copper equipment grounding conductor
  • required for a 200-amp feeder?

A. 6 AWG

B. 8 AWG

C. 4 AWG

D. 2 AWG

Rationale: NEC Table 250.122 specifies a 4 AWG copper grounding

conductor for 200-amp overcurrent protection.

  • Underground service-lateral conductors that are not encased in

concrete must have a minimum cover of:

  • 12 inches
  • 18 inches
  • 24 inches
  • 30 inches

Rationale: NEC Table 300.5 requires 24″ cover for direct-buried service

conductors.

  • The maximum number of 90° bends allowed in a single conduit run

between pull points is:

  • 2
  • 3

C. 4 1 / 3

  • 5

Rationale: NEC 358.26 and similar articles limit total bends to 360°.

  • What is the minimum ampacity required for service conductors
  • supplying a 120/240-V, 1-phase, 200-amp service?

A. 150 A

B. 160 A

C. 180 A

D. 200 A

Rationale: Service conductors must not be smaller than the service rating

(NEC 230.42).

  • Type NM cable is NOT permitted in which location?
  • Wood-framed walls
  • Above suspended ceilings in dwellings
  • Commercial garages
  • Residential attics

Rationale: NEC 334 prohibits NM in commercial garages due to hazardous

conditions.

  • What is the maximum voltage drop recommended for a branch circuit
  • feeder and branch combined?

  • 2%
  • 3%
  • 5%
  • 8%

Rationale: NEC FPN recommends 3% branch, 5% total.

  • The grounded (neutral) conductor in a 120/240-V system must be
  • identified by which color?

  • Red
  • White
  • Blue
  • Orange
  • Rationale: NEC 200.6 requires neutrals to be white or gray. 2 / 3

8. Minimum working clearance in front of 480-V electrical panels is:

  • 2 ft
  • 2.5 ft
  • 3 ft
  • 3.5 ft

Rationale: NEC Table 110.26(A)(1) requires 3 ft for most 480-V

equipment.

  • What is the maximum continuous load allowed on a 20-A branch
  • circuit?

A. 12 A

B. 14 A

C. 16 A

D. 20 A

Rationale: 80% rule for continuous loads (NEC 210.20).

  • Which conductor material is NOT acceptable for grounding
  • electrodes?

  • Copper
  • Zinc-coated steel
  • Aluminum
  • Stainless steel

Rationale: NEC 250.62 prohibits aluminum for grounding electrodes due

to corrosion.

  • Minimum burial depth for rigid metal conduit under a driveway?

A. 6″

B. 12″

C. 18″

D. 24″

Rationale: NEC Table 300.5 requires 24″ under driveways.

  • Maximum rating for a single receptacle on a 20-amp circuit?
  • / 3

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

This document featured in-depth analysis that enhanced my understanding. Such an superb resource!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 3, 2026
Description:

Florida Certified Master Electrician Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf 1. What is the minimum size copper equipment grounding conduc...

Unlock Now
$ 1.00