Florida Certified Plumbing Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf

  • What is the minimum slope required for a 3-inch horizontal drainage
  • pipe under the Florida Plumbing Code?

  • 1/8 inch per foot
  • 1/4 inch per foot
  • 3/8 inch per foot
  • 1/2 inch per foot

Rationale: The code requires a minimum slope of 1/4 inch per foot for

drainage piping 3 inches or smaller to maintain proper flow.

  • What is the minimum required air gap for a fixture outlet under the
  • Florida Plumbing Code?

  • 1× the fixture outlet diameter
  • 2× the fixture outlet diameter
  • 3× the fixture outlet diameter
  • 4× the fixture outlet diameter

Rationale: The minimum air gap is twice the fixture outlet diameter to

prevent backflow.

  • / 3
  • The maximum distance from a trap to its vent for a 1½-inch trap arm

is:

  • 2 feet
  • 3 feet
  • 3 feet 6 inches
  • 5 feet

Rationale: A 1½-inch trap arm may be up to 3 feet 6 inches in developed

length to the vent.

  • A cleanout must be installed so that it is accessible and located no
  • more than how many feet apart in a building drain?

  • 50 feet
  • 100 feet
  • 75 feet
  • 125 feet

Rationale: The code requires cleanouts every 100 feet on horizontal

drainage runs.

  • What is the minimum size building sewer permitted?
  • 2 inches
  • 3 inches
  • 4 inches
  • 6 inches

Rationale: A building sewer must be at least 4 inches in diameter by

Florida code.

  • The minimum working pressure for potable water supply piping

inside a building must be: 2 / 3

  • 10 psi
  • 15 psi
  • 20 psi
  • 25 psi

Rationale: The code specifies a minimum of 20 psi for water distribution

systems.

  • A water service pipe must be installed at least how deep below grade?
  • 6 inches
  • 8 inches
  • 12 inches
  • 12 inches plus frost depth (if applicable)

Rationale: Florida requires at least 12 inches of cover, with adjustments in

freeze zones.

  • Which material is NOT permitted for water distribution inside a
  • building?

  • Copper

B. CPVC

C. PEX

D. PVC

Rationale: PVC may not be used for interior hot or cold potable water

distribution.

  • A pressure relief valve on a water heater must discharge to a

termination point no more than:

  • 2 inches above the floor
  • 4 inches above the floor
  • 6 inches above the floor
  • / 3

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

This document provided in-depth analysis, which was a perfect resource for my project. Absolutely superb!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 3, 2026
Description:

Florida Certified Plumbing Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf 1. What is the minimum slope required for a 3-inch horizonta...

Unlock Now
$ 1.00