Florida Certified Plumbing Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf
- What is the minimum slope required for a 3-inch horizontal drainage
- 1/8 inch per foot
- 1/4 inch per foot
- 3/8 inch per foot
- 1/2 inch per foot
pipe under the Florida Plumbing Code?
Rationale: The code requires a minimum slope of 1/4 inch per foot for
drainage piping 3 inches or smaller to maintain proper flow.
- What is the minimum required air gap for a fixture outlet under the
- 1× the fixture outlet diameter
- 2× the fixture outlet diameter
- 3× the fixture outlet diameter
- 4× the fixture outlet diameter
Florida Plumbing Code?
Rationale: The minimum air gap is twice the fixture outlet diameter to
prevent backflow.
- / 3
- The maximum distance from a trap to its vent for a 1½-inch trap arm
is:
- 2 feet
- 3 feet
- 3 feet 6 inches
- 5 feet
Rationale: A 1½-inch trap arm may be up to 3 feet 6 inches in developed
length to the vent.
- A cleanout must be installed so that it is accessible and located no
- 50 feet
- 100 feet
- 75 feet
- 125 feet
more than how many feet apart in a building drain?
Rationale: The code requires cleanouts every 100 feet on horizontal
drainage runs.
- What is the minimum size building sewer permitted?
- 2 inches
- 3 inches
- 4 inches
- 6 inches
Rationale: A building sewer must be at least 4 inches in diameter by
Florida code.
- The minimum working pressure for potable water supply piping
inside a building must be: 2 / 3
- 10 psi
- 15 psi
- 20 psi
- 25 psi
Rationale: The code specifies a minimum of 20 psi for water distribution
systems.
- A water service pipe must be installed at least how deep below grade?
- 6 inches
- 8 inches
- 12 inches
- 12 inches plus frost depth (if applicable)
Rationale: Florida requires at least 12 inches of cover, with adjustments in
freeze zones.
- Which material is NOT permitted for water distribution inside a
- Copper
building?
B. CPVC
C. PEX
D. PVC
Rationale: PVC may not be used for interior hot or cold potable water
distribution.
- A pressure relief valve on a water heater must discharge to a
termination point no more than:
- 2 inches above the floor
- 4 inches above the floor
- 6 inches above the floor