Limited Energy Technician Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the maximum voltage permitted for a Class 2 circuit under
- 60 volts
- 30 volts
- 50 volts
- 100 volts
normal conditions?
Rationale: Class 2 circuits are limited to 30 volts maximum under
normal operating conditions to reduce shock hazards.
- Which NEC Article covers Fire Alarm Systems?
- Article 725
- Article 760
- Article 800 1 / 4
- Article 820
Rationale: Fire alarm systems are governed by NEC Article 760.
- What is the primary purpose of a Class 1 circuit?
- Data transmission
- Audio communications
- Remote control and signaling
- Computer networking
Rationale: Class 1 circuits are designed for remote control and
signaling purposes where higher voltage or power may be required.
- Which conductor color is typically used for negative polarity in DC
- White
- Green
- Blue
- Red
control circuits?
Rationale: Blue is commonly used to indicate the negative or grounded
side in DC control wiring.
- What is the minimum bending radius for a communication cable
- 2 times cable diameter
- 4 times cable diameter
- As specified by the manufacturer
- 10 times cable diameter 2 / 4
according to manufacturer’s instructions?
Rationale: The NEC defers to manufacturer instructions for bending
radius limits to prevent cable damage.
- What type of cable is rated for plenum use?
- CM
B. CMR
C. CMP
D. CAT6
Rationale: CMP-rated cable is designed for plenum spaces and meets
stringent fire-resistance requirements.
- Which NEC Article governs communication circuits?
A. 725
B. 760
C. 800
D. 805
Rationale: Article 800 of the NEC covers communication circuits such
as telephone and data wiring.
- What type of wire insulation is required in a fire-rated cable system?
- Polyethylene
- Fire-resistant insulation
C. PVC
- Nylon
Rationale: Fire-rated systems require insulation materials designed to
resist flame propagation. 3 / 4
- Which color must never be used for an ungrounded conductor?
- Red
- Blue
- Green
- Black
Rationale: Green is reserved exclusively for grounding conductors.
- In a low-voltage lighting system, transformers must be listed for
- Power distribution
- Low-voltage lighting
- Industrial control
- Communication
what type of use?
Rationale: Transformers must be listed specifically for low-voltage
lighting to ensure proper safety compliance.
- What is the maximum voltage permitted for Class 3 circuits?
- 24 volts
- 30 volts
- 100 volts
- 150 volts
Rationale: Class 3 circuits can operate up to 100 volts under normal
conditions.
- / 4