Master Plumber Licensing Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
1. The minimum slope for a 3-inch horizontal drainage pipe is:
- 1/8 inch per foot
- 1/4 inch per foot
- 3/8 inch per foot
- 1/2 inch per foot
Rationale: The Uniform Plumbing Code requires a minimum slope of 1/4
inch per foot for 2½-inch to 3-inch pipes to ensure proper flow velocity.
- What is the maximum vertical distance between a trap weir and the vent
- 24 inches
- 6 inches
- 12 inches 1 / 4
opening?
- 18 inches
Rationale: The vent opening must be located within 6 inches of the trap
weir to prevent siphonage.
- A cleanout is required for every building drain line at intervals not
exceeding:
- 50 feet
- 75 feet
- 100 feet
- 150 feet
Rationale: Code requires cleanouts at not more than 100 feet apart for
horizontal drainage lines.
4. The main vent stack should extend through the roof not less than:
- 4 inches above the roof
- 6 inches above the roof
- 8 inches above the roof
- 12 inches above the roof
Rationale: Minimum extension above the roof is 6 inches to prevent
obstruction from snow or debris.
5. The air gap for an indirect waste pipe shall be at least:
- Twice the diameter of the waste pipe
- Equal to the pipe diameter
- 1 inch minimum
- 1.5 times the pipe diameter 2 / 4
Rationale: Code mandates an air gap twice the diameter of the outlet to
prevent backflow.
6. The minimum size of a building sewer serving one water closet is:
- 2 inches
- 3 inches
- 4 inches
- 5 inches
Rationale: A 4-inch sewer line is the minimum allowed for a system with at
least one toilet.
7. The trap seal depth must be between:
- 1–2 inches
- 2–4 inches
- 4–6 inches
- 6–8 inches
Rationale: Trap seals must be deep enough to prevent sewer gas but
shallow enough to avoid siphonage.
- The maximum length of a trap arm (2-inch diameter) without an
additional vent is:
- 3 feet
- 5 feet
- 6 feet
- 8 feet 3 / 4
Rationale: Code limits the trap arm length for 2-inch pipe to 5 feet from
trap weir to vent.
- Which type of fitting should be used to connect a vertical drain to a
- Sanitary tee
- Wye or combination wye and 1/8 bend
- Cross fitting
- Street elbow
horizontal drain?
Rationale: Wye-type fittings promote smooth flow transition from vertical
to horizontal.
10. The minimum water service pipe size for a single-family dwelling is:
- 1/2 inch
- 3/4 inch
- 1 inch
- 5/8 inch
Rationale: A 3/4-inch service line ensures adequate flow and pressure for
domestic use.
11. The minimum vent pipe size for a water closet is:
- 1.5 inches
- 2.5 inches
- 2 inches
- / 4