Alarm System Installer Licensing Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the primary purpose of an alarm system?
- To replace law enforcement
- To detect and alert of unauthorized entry or hazards
- To monitor building temperature
- To control lighting
Rationale: The main function of alarm systems is to detect intrusions, fire,
or other hazards and provide alerts for security and safety.
- Which of the following is a key component of a burglar alarm system?
- Air pressure sensor
- Motion detector
- Smoke detector
- Fire alarm bell 1 / 4
Rationale: Burglar alarms commonly use motion detectors to sense
unauthorized movement within a protected area.
3. The control panel in an alarm system primarily functions to:
- Supply power to the sensors
- Process signals from sensors and activate alarms
- Store video footage
- Control building lighting
Rationale: The control panel receives and interprets input from sensors and
triggers alarm outputs accordingly.
4. A closed-circuit alarm loop means:
- The circuit is connected to external networks
- The circuit is complete under normal conditions
- The circuit is broken during normal conditions
- The system uses wireless signals
Rationale: In a closed-circuit loop, the electrical path is complete until
interrupted by intrusion, triggering the alarm.
- What type of sensor detects the breaking of glass?
- Ultrasonic sensor
- Acoustic sensor 2 / 4
- Infrared sensor
- Temperature sensor
Rationale: Acoustic sensors detect specific sound frequencies produced
when glass breaks.
- Which power supply component provides backup in case of main power
- Transformer
- Battery backup
- Voltage regulator
- Rectifier
failure?
Rationale: A backup battery ensures continuous operation when primary
power is lost.
7. NFPA 72 primarily governs:
- Electrical wiring methods
- Fire alarm systems installation and maintenance
- Burglar alarm licensing
- CCTV operations
Rationale: NFPA 72 is the National Fire Alarm and Signaling Code, outlining
fire alarm system standards.
- / 4
- What type of cable is commonly used for alarm circuits?
- Coaxial
- Twisted pair
- Fiber optic
- Flat ribbon
Rationale: Twisted pair cable reduces electromagnetic interference and is
standard for alarm wiring.
- Which of the following provides protection against voltage surges?
- Breaker
- Fuse
- Surge protector
- Transformer
Rationale: Surge protectors divert excess voltage to prevent damage to
system components.
10. A Normally Closed (NC) contact in an alarm circuit will:
- Be open when system is armed
- Stay closed until an alarm condition occurs
- Stay open under all conditions
- Require manual reset
Rationale: NC contacts maintain a closed path until the circuit is
interrupted by intrusion or fault.
- / 4