- What does BICSI stand for?
- Building Industry Consulting Service International
- Building Infrastructure Cabling Standards Institute
- Building Industry Consulting Service International, Inc.
- Broadband Infrastructure and Communication Systems
International
Rationale: BICSI stands for Building Industry Consulting Service
International, Inc., which develops standards and provides training and certifications in the information and communications technology (ICT) industry.
2. The primary role of a BICSI Installer 1 is to:
- Design telecommunications systems
- Install and terminate low-voltage cabling systems 1 / 4
- Inspect telecommunications facilities
- Certify network systems
Rationale: Installer 1 professionals focus on installation, termination,
and basic testing of copper and optical fiber cabling systems.
- What is the maximum horizontal cabling length allowed by TIA/EIA
- 150 meters
- 90 meters
- 100 meters
- 120 meters
standards?
Rationale: The maximum horizontal cabling length is 90 meters for
permanent link, plus up to 10 meters for patch cords.
- Which of the following cables is typically used for horizontal cabling?
A. RG-6
- Coaxial cable
- Category 6 UTP cable
- Shielded twisted pair Category 3
Rationale: Category 6 UTP cable is the standard choice for horizontal
cabling due to its high bandwidth and reduced crosstalk.
5. The function of the patch panel is to:
- Protect cable from electromagnetic interference
- Connect two buildings together
- Terminate horizontal cables and provide patching connections 2 / 4
- Amplify network signals
Rationale: Patch panels serve as termination points for horizontal
cables, allowing flexible connections to network equipment.
- Which color code standard is more common in the U.S. for T568A and
T568B wiring?
A. T568A
B. T568B
- Both equally
- None
Rationale: Although both are recognized, T568B is more commonly
used in the U.S. for consistency with older systems.
- What tool is used to terminate cables on a 110-type block?
- Crimping tool
- Cable stripper
- Punch-down tool
- Wire cutter
Rationale: A punch-down tool is used to seat and cut wires onto
insulation displacement contacts (IDC) on a 110-type block.
8. When installing cable in a plenum space, you must use:
- PVC-jacketed cable
- Non-plenum cable
- Plenum-rated cable (CMP)
- Riser-rated cable 3 / 4
Rationale: Plenum-rated cables have low-smoke and low-toxicity
jackets suitable for use in air-handling spaces.
- Which of the following is a safety precaution before starting a ladder
- Make sure it’s near power lines
- Test for static
- Inspect the ladder for defects
- Tie it with a cable
installation?
Rationale: Inspecting the ladder ensures it is stable and safe for use,
preventing falls or injuries.
10. The most common cause of crosstalk in twisted-pair cables is:
- Excessive cable length
- Untwisting too much of the pair during termination
- Using shielded cable
- Grounding issues
Rationale: Untwisting more than ½ inch of cable pairs can increase
near-end crosstalk, degrading performance.
11. A riser-rated cable (CMR) is used for:
- Open air plenums
- Vertical runs between floors
- Underground conduits
- Outdoor aerial installations