- What is the primary responsibility of a BICSI Technician?
- Designing structured cabling systems
- Installing, terminating, testing, and troubleshooting structured cabling
- Managing construction schedules
- Inspecting electrical conduit installations
systems
Rationale: The BICSI Technician ensures proper installation, termination,
and testing of structured cabling in accordance with standards.
- Which standard defines the commercial building telecommunications
- NEC Article 800
- ANSI/TIA-568 series 1 / 4
cabling system?
C. ISO/IEC 11801
D. IEEE 802.3
Rationale: The ANSI/TIA-568 series outlines the requirements for
commercial building telecommunications cabling systems.
- What is the minimum bend radius for UTP cable during installation?
- 1x the cable diameter
- 2x the cable diameter
- 4x the cable diameter
- 8x the cable diameter
Rationale: The minimum bend radius for UTP cable is four times the cable
diameter to prevent signal loss or damage.
- When pulling copper cables, what is the maximum pulling tension?
- 10 lbf
- 15 lbf
- 25 lbf
- 50 lbf
Rationale: The maximum recommended pulling tension for a four-pair UTP
cable is 25 pounds-force to avoid stretching or damaging the pairs.
- / 4
- What type of connector is commonly used on coaxial cable?
- F-type
B. RJ-45
- SC
- LC
Rationale: F-type connectors are standard for coaxial cables in video and
broadband applications.
- Which color pair is used for pins 4 and 5 in a T568B termination?
- Orange
- Blue
- Green
- Brown
Rationale: In T568B, the blue pair (pair 1) occupies pins 4 and 5.
- Which tool is used to install UTP cable conductors into IDC terminals?
- Crimping tool
- Punch-down tool
- Stripping tool
- Tone generator
Rationale: A punch-down tool seats and terminates wires into insulation
displacement connectors. 3 / 4
- Which of the following is a characteristic of Category 6A cable?
- Supports up to 100 MHz
- Uses RG-6 connectors
- Is used only for telephone systems
- Supports 10 Gigabit Ethernet up to 100 meters
Rationale: Category 6A is rated for 10GBASE-T Ethernet at 100 meters.
- What is the maximum distance for a copper horizontal cabling run
- 50 meters
- 90 meters
- 100 meters
- 120 meters
according to TIA?
Rationale: The horizontal permanent link is limited to 90 meters, with
patch cords totaling 10 meters.
- What is the main function of a patch panel?
- To boost network signal strength
- To organize and connect horizontal cabling to network equipment
- To serve as a data switch
- To test network cables