FDNY G71 Supervision Of Piped Non- Flammable Medical Gases Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the primary purpose of the FDNY G71 certificate?
- To supervise flammable gases
- To supervise piped non-flammable medical gases
- To install oxygen tanks
- To supervise gas welding operations
Rationale: The G71 specifically authorizes supervision of piped non-
flammable medical gases in hospitals and similar facilities.
- Which of the following is considered a non-flammable medical gas?
- Acetylene
- Oxygen 1 / 4
- Propane
- Hydrogen
Rationale: Oxygen is non-flammable but supports combustion; it is
classified as a medical gas.
- Who may operate medical gas systems under supervision?
- Any employee in the building
- Temporary contractors
- Only trained and authorized personnel
- Security personnel
Rationale: FDNY regulations allow only properly trained and
authorized personnel to interact with the system.
- What is the minimum distance medical gas cylinders must be kept
- 1 foot
- 2 feet
- 3 feet
- 6 feet
from combustible materials?
Rationale: The safety standard generally requires separation of gas
cylinders from combustibles by at least 3 feet.
- What does the color green commonly indicate in medical gas piping?
- Nitrogen
- Oxygen
- Vacuum lines 2 / 4
- Carbon dioxide
Rationale: US and NYC medical gas piping conventionally uses green
for oxygen.
- Which agency issues the G71 certificate?
A. DOH
B. OSHA
C. EPA
D. FDNY
Rationale: The FDNY (Fire Department of New York) is the issuing
authority for the certification.
- Which gas is commonly used for patient anesthesia?
- Oxygen
- Nitrogen
- Nitrous oxide
D. CO₂
Rationale: Nitrous oxide is frequently used as an anesthetic gas.
- Where must main shutoff valves for medical gas systems be located?
- Random valve placements
- In utility basements only
- In clearly marked and accessible locations
- Hidden behind locked panels
Rationale: Emergency shutoffs must be visible and accessible for
safety. 3 / 4
9. The G71 holder must ensure gas alarms:
- Are disconnected during maintenance
- Are always operational
- Are only tested yearly
- Are optional
Rationale: Proper functioning of gas alarms is required at all times.
10. Cylinders must be stored:
- Horizontally on the floor
- Secured upright
- Leaning against the wall
- In any convenient position
Rationale: Upright, secured storage prevents hazards such as falling
or valve damage.
11. The pressure in a piped medical oxygen line is typically:
- 5–10 psi
- Around 50 psi
- 150 psi
- 500 psi
Rationale: Medical oxygen delivery systems commonly operate
around 50 psi.
12. The piping for medical gases must be made of:
A. PVC
- Copper tubing
- / 4