Class notes Jan 3, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

FDNY S89 Certification of Corrected Fire Alarm System Defects (Citywide) Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf

  • A fire alarm system is required to be restored within how many hours
  • after a defect is corrected?

  • 12 hours
  • 24 hours
  • 48 hours
  • 72 hours

Rationale: Fire alarm defects must be corrected and restored

promptly, typically within 48 hours to ensure continuous safety coverage.

  • Which of the following is a common cause of a trouble signal in a fire
  • alarm system? 1 / 4

  • Alarm activation
  • Open or short circuit in wiring
  • Smoke detection
  • Power surge

Rationale: Open or short circuits in the wiring often cause trouble

signals, indicating the system is not fully operational.

  • When correcting a fire alarm system defect, which document must be
  • updated?

  • Daily log
  • FDNY S89 Correction Report
  • Building permit
  • Fire department inspection notice

Rationale: The S89 Correction Report documents the corrected defect

to maintain compliance with FDNY regulations.

  • In a sprinkler system-connected fire alarm, a defective water flow

switch will:

  • Trigger a test signal
  • Cause a supervisory signal until repaired
  • Silence all alarms
  • Reset the alarm panel automatically

Rationale: Supervisory signals indicate a problem with components

like water flow switches in sprinkler systems, alerting maintenance personnel. 2 / 4

5. A smoke detector that frequently triggers false alarms may indicate:

  • Fire presence
  • Improper placement or contamination
  • Normal operation
  • Low battery

Rationale: Dust, debris, or incorrect placement can cause nuisance

alarms and must be corrected for proper function.

  • Which type of fire alarm system requires a licensed FDNY professional
  • to perform corrections?

  • Residential battery-operated
  • Portable smoke detectors
  • Citywide fire alarm systems
  • Personal alert devices

Rationale: Citywide fire alarm systems require certified technicians

for corrections due to complexity and regulatory compliance.

7. A "trouble signal" at a fire alarm control panel indicates:

  • Active fire condition
  • System test mode
  • System defect or fault
  • Battery fully charged

Rationale: Trouble signals indicate defects, malfunctions, or

abnormal conditions that need correction. 3 / 4

  • After correcting a fire alarm defect, which action is required?
  • Wait for FDNY to inspect
  • Notify building tenants only
  • Submit correction documentation to FDNY
  • Test the system once per year

Rationale: Documentation confirms the defect has been corrected

and ensures compliance.

  • Which component is typically checked first when a fire alarm system
  • reports a trouble signal?

  • Fire alarm panel display
  • Sprinkler heads
  • Wiring and connections
  • Alarm bell volume

Rationale: Wiring issues are a frequent cause of trouble signals and

should be inspected first.

  • What is the primary purpose of the FDNY S89 Certification?
  • Ensure firefighters are trained
  • Inspect hydrants
  • Certify corrected fire alarm system defects
  • Approve new building permits

Rationale: The S89 Certification verifies that previously reported

defects in fire alarm systems have been corrected.

  • / 4

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

This document provided step-by-step guides, which was incredibly useful for my research. Absolutely remarkable!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 3, 2026
Description:

FDNY S89 Certification of Corrected Fire Alarm System Defects (Citywide) Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf 1. A fire ala...

Unlock Now
$ 1.00