CA C45 Electrical Sign Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf
- Which component in a neon sign increases voltage to illuminate the
- Resistor
- Capacitor
- Transformer
- Ballast
gas?
Rationale: Neon signs require high voltage to ionize the gas inside
the tubes; transformers step up standard voltage to the required level.
- What is the primary purpose of grounding an electrical sign?
- Reduce energy consumption
- Improve lighting efficiency
- Prevent electric shock
- Enhance appearance
Rationale: Grounding provides a safe path for fault current,
protecting people from electric shock.
- For outdoor sign wiring, which wire type is recommended for direct
burial?
A. THHN
- Romex
C. UF-B
D. NM-B
Rationale: UF-B wire is rated for wet conditions and direct burial
without conduit. 1 / 3
- Which NEC article governs electrical sign installation?
A. 210
B. 310
C. 600
D. 725
Rationale: NEC Article 600 covers installation, wiring, grounding,
and safety requirements for electrical signs.
- When installing multiple signs on a single circuit, what must be
- Sign color
- Mounting height
- Total current load
- Wire insulation
calculated?
Rationale: Calculating total current load prevents overloading the
circuit and tripping breakers.
- What is the main hazard of high-voltage neon transformers?
- Low brightness
- Overheating bulbs
- Electric shock
- Short lifespan
Rationale: High-voltage transformers can deliver dangerous
currents; improper handling can result in electrocution.
- Which type of conduit is most resistant to corrosion in outdoor
environments?
A. EMT
- RMC uncoated
- PVC or coated metal
- Flexible metal
Rationale: PVC and coated metal resist moisture and corrosion,
making them suitable for outdoor use.
- For fluorescent signs, which device regulates current through the tubes?
- Transformer
- Switch
- Ballast
- Dimmer
Rationale: The ballast prevents excessive current that could damage
the tubes. 2 / 3
- What is the maximum voltage drop recommended for long sign wiring
- 1%
- 3%
- 5%
runs?
D. 10%
Rationale: A 5% voltage drop ensures proper operation without
excessive energy loss.
- What protective device is required for outdoor wet-location
- Arc-fault breaker
- Surge protector
signs?
C. GFCI
- Standard breaker
Rationale: GFCI protection interrupts current during faults,
preventing shock in wet conditions.
- What is the minimum pedestrian clearance for projecting signs?
- 6 feet
- 7 feet
- 8 feet
- 10 feet
Rationale: Most building codes require 8 feet clearance to prevent
pedestrian injury.
- Which mounting hardware is suitable for concrete or masonry
- Wood screws
- Sheet metal screws
- Expansion anchors
- Staples
walls?
Rationale: Expansion anchors provide secure attachment in masonry
where screws alone are insufficient.
- When connecting neon tubes in a sign, how should they be
- Series
- Series-parallel without load check
- Parallel with proper load calculation
- Direct to neutral
- / 3
wired?