FDNY F92 Fire Guard for Boatyards/Marinas and to Supervise Boatyards/Marinas Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the primary responsibility of a Fire Guard in a boatyard or
- Inspecting boats for mechanical defects
- Preventing and responding to fires
- Supervising dock workers
- Conducting sailing lessons
marina?
Rationale: The primary role of a Fire Guard is to prevent fires and
ensure safety in areas with high fire hazards.
- Which NFPA standard covers the fire safety requirements for marinas?
A) NFPA 1
B) NFPA 303 1 / 4
C) NFPA 70
D) NFPA 101
Rationale: NFPA 303 is the standard specifically for marinas and
boatyards, outlining fire protection requirements.
3. In a boatyard, flammable liquids should be stored:
- In open containers
- On the docks
- In approved flammable liquid storage cabinets
- Under boats
Rationale: Flammable liquids must be stored safely in approved
cabinets to minimize fire hazards.
- Before any hot work in a marina, what must be done?
- Notify dock owners
- Clean the boat deck
- Obtain a hot work permit and inspect the area
- Schedule maintenance
Rationale: A hot work permit ensures proper precautions are taken
before activities like welding or cutting.
- Which type of extinguisher is required for gasoline fires in a marina?
- Water
- Foam
- Dry chemical (Class B)
- CO₂ only 2 / 4
Rationale: Class B extinguishers are suitable for flammable liquid fires,
such as gasoline.
- When supervising a boatyard, how often should fire safety inspections
- Annually
- Daily
- Monthly
- Weekly
be conducted?
Rationale: Frequent inspections help identify hazards early and
maintain fire safety compliance.
- What is the minimum number of fire extinguishers required for a small
- One
- Two
- At least one easily accessible extinguisher
- None
marina office?
Rationale: Even small offices must have at least one accessible
extinguisher in compliance with FDNY regulations.
- What is the maximum allowable amount of flammable liquid in an
- 5 gallons
- 10 gallons
- 15 gallons 3 / 4
open work area?
- 20 gallons
Rationale: NFPA 303 and FDNY regulations limit quantities in work
areas to reduce fire risk.
- Which of the following is a common fire hazard in a marina?
- Overcrowded docks
- Faulty boat wiring
- Fuel spills
- All of the above
Rationale: All listed hazards can contribute to fire incidents in marinas.
- When supervising fire safety, what is the first action if a fire
- Call the fire department
- Activate alarms and use extinguishers if safe
- Evacuate immediately
- Remove boats from the dock
starts?
Rationale: Immediate response involves alerting others and
attempting to extinguish the fire safely.
- Hot work permits in a boatyard are required for which activities?
- Painting
- Cleaning
- Welding, grinding, or cutting
- Dock maintenance
- / 4