- Which of the following is the primary magnetic field strength of a
- 0.1–0.2 Tesla
- 0.5–1 Tesla
- 1.5–3 Tesla
- 5–7 Tesla
clinical MRI scanner?
Rationale: Clinical MRI scanners commonly operate at 1.5 to 3 Tesla,
balancing image quality and patient safety.
2. The Larmor frequency is defined as the frequency at which:
- Protons move in a circle 1 / 4
- Nuclear spins precess around the magnetic field
- RF coils emit energy
- Magnetic gradients are applied
Rationale: The Larmor frequency is the rate at which nuclear spins
precess in the magnetic field, fundamental for MRI signal detection.
- What is the primary reason gadolinium-based contrast agents are used
- To increase tissue density
- To reduce scan time
- To enhance T1-weighted signal
- To suppress fat signal
in MRI?
Rationale: Gadolinium shortens T1 relaxation times, increasing signal
intensity on T1-weighted images, improving lesion detection.
- Which pulse sequence is most sensitive to detecting edema?
- T1-weighted
- Proton density
- T2-weighted
- Gradient echo
Rationale: T2-weighted sequences highlight water content, making
them sensitive to edema and inflammation.
5. SAR (Specific Absorption Rate) in MRI refers to:
- The magnetic field strength
- The rate of RF energy absorbed by the body 2 / 4
- Gradient coil efficiency
- Slice selection speed
Rationale: SAR measures the RF energy deposited in tissue, critical
for patient safety and regulatory compliance.
- Which of the following MRI sequences is most useful for visualizing
- Spin echo
- T1-weighted
anatomy of the brain in multiple planes rapidly?
C. FLAIR
- Diffusion-weighted
Rationale: FLAIR suppresses CSF and highlights pathology, making it
highly useful for brain imaging in multiple planes.
7. In MRI, “echo time” (TE) refers to:
- The time between RF pulse and start of gradient
- The time between two RF pulses
- The time between the RF pulse and the peak of the echo signal
- The total scan duration
Rationale: TE determines T2-weighting; it is the time from RF
excitation to signal measurement.
- A patient has a pacemaker. Which statement is true regarding MRI?
- MRI is always safe
- MRI is safe at low field only
- MRI is contraindicated unless pacemaker is MRI-conditional 3 / 4
- MRI can be performed with standard monitoring
Rationale: Traditional pacemakers are unsafe in MRI due to risk of
heating, malfunction, and arrhythmia. MRI-conditional devices may be scanned under strict protocols.
9. The function of a gradient coil is to:
- Produce the main magnetic field
- Detect MR signals
- Spatially encode the MR signal
- Suppress fat
Rationale: Gradient coils create linear variations in the magnetic
field, enabling spatial localization of signals.
- Which MRI artifact is caused by patient motion?
- Aliasing
- Ghosting
- Susceptibility
- Chemical shift
Rationale: Motion during the scan produces ghosting along the
phase-encoding direction.
11. Proton density weighting is achieved by using:
- Long TR and short TE
- Short TR and long TE
- Long TR and short TE
- Short TR and short TE
- / 4