FDNY Z51 EXAM REAL EXAM QUESTIONS AND VERIFIED

Exam (elaborations) Dec 15, 2025 ★★★★★ (5.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

Page 1 of 56

SUCCESS!

1

FDNY Z51 EXAM REAL EXAM QUESTIONS AND VERIFIED

ANSWERS LATEST VERSION -

A refrigeration compressor has failed to turn on. The refrigeration engineer on duty verifies that the electrical circuit to the motor, including all switches and circuit breakers, is complete according to recommended service practice. The next item to be checked would likely by the

  • temperature and pressure controls.
  • refrigerant charge.
  • cooling tower operation.
  • liquid-line solenoid valve. - ANSWER✔✔A) temperature and pressure controls.

The use of oil in the refrigeration machine is to

  • Add non-condensates to refrigerant.
  • Mix the oil with liquid refrigerant.
  • Reduce wear and friction in compressor parts.
  • None of the answers are correct. - ANSWER✔✔C) Reduce wear and friction in compressor
  • parts.

  • / 4

Page 2 of 56

SUCCESS!

2 The heat removed from the refrigerant condenser is

  • latent heat only.
  • sensible heat only.
  • sensible and latent heat.
  • Radiant heat only. - ANSWER✔✔C) sensible and latent heat.

Which service valve should be installed in a dual pressure release valve while keeping system in service?

  • Two-way valve.
  • Plug valve.
  • Three-way valve.
  • Stop valve. - ANSWER✔✔C) Three-way valve.

The monthly quick check of a fire extinguisher does NOT include

  • Checking the extinguisher for damage.
  • Confirming its proper location. 2 / 4

Page 3 of 56

SUCCESS!

3

  • Discharging the extinguisher.
  • Ensuring it is clear from any obstructions. - ANSWER✔✔C) Discharging the extinguisher.

Several components of a sprinkler system in an office building need to be repaired. Which of the following are allowed to perform the repair work?

  • A Q-01 refrigeration engineer holding S-12 CoF.
  • A Master Fire Suppression Contractor holding S-12 CoF.
  • Any Master Fire Suppression Piping Contractor.
  • A S-12 CoF holder without any other license. - ANSWER✔✔B) A Master Fire Suppression
  • Contractor holding S-12 CoF.

A FDNY permit is required to conduct hot work for

  • brazing.
  • welding.
  • use of oxygen and flammable gas.
  • All answers are correct - ANSWER✔✔D) All answers are correct

Which of the following correctly describes the object in the picture below? 3 / 4

Page 4 of 56

SUCCESS!

4

  • Carbon dioxide system nozzle, to extinguish electrical fires.
  • Cooling tower makeup valve, to put out fires in case of emergency.
  • Standpipe hose outlet, to put out fires in case of emergency.
  • Water chemistry supply station, for condenser water. - ANSWER✔✔C) Standpipe hose outlet,
  • to put out fires in case of emergency.

While on duty, a refrigerant engineer notices that the suction line to the compressor and part of the compressor is frosted. Of the following, the most likely reason for this condition is

  • the TEV is almost closed.
  • overcharge.
  • there is a blockage in the liquid line
  • low condenser water temperature. - ANSWER✔✔B) overcharge.

You find that the check valve on a centrifugal pump is leaking. When will the most damage be caused to the pump?

  • When another pump is turned on.
  • On shutdown.
  • / 4

User Reviews

★★★★★ (5.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★★

I was amazed by the in-depth analysis in this document. It helped me ace my presentation. Truly excellent!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Exam (elaborations)
Added: Dec 15, 2025
Description:

SUCCESS! FDNY Z51 EXAM REAL EXAM QUESTIONS AND VERIFIED ANSWERS LATEST VERSION - A refrigeration compressor has failed to turn on. The refrigeration engineer on duty verifies that the electrical ci...

Unlock Now
$ 1.00