PDF Download
FREE AND STUDY GAMES ABOUT 2208- RODINA MIDTERM
EXAM QUESTIONS
Actual Qs and Ans Expert-Verified Explanation
This Exam contains:
-Guarantee passing score -87 Questions and Answers -format set of multiple-choice -Expert-Verified Explanation Question 1: On APU's equipped with a free turbine and load compressor, the primary function of the load compressor is to
Answer:
provide bleed air for aircraft pneumatic systems.
Question 2: Oxygen used in aircraft systems is what?
Answer:
is at least 99.5 percent pure and is practically water free.
Question 3: pressure measured in inches of mercury, absolute?
Answer:
barometric pressure Question 4: the pressure in the cabin of an airplane is usually designated as not psi?
Answer:
cabin altitude
Question 5: DOT 3AA cylinder hydro test psi?
Answer:
3,085 psi Question 6: Before a high-pressure oxygen cylinder is serviced, it must be the correct type and have been?
Answer:
hydrostatically tested within the proper time interval.
Question 7: What to do if the system has a leak?
Answer:
Bubble test with a special Question 8: valve used to stop decompression of the A/C if the delivery air check valve is inoperable?
Answer:
SOV Question 9: What test is used to determine the serviceability of an oxygen cylinder?
Answer:
Pressure test with water.
Question 10: what operates the outflow valve on most large A/C?
Answer:
electric motor Question 11: Composite oxygen bottles that conform to DOT-E-8162 have a service life of?
Answer:
15 years or 10,000 filling cycles whichever occurs first.
Question 12: demand system is for?
Answer:
O2 is delivered when user inhales
Question 13: Uses a re-breather bag?
Answer:
Continuous flow system
Question 14: What is Stenciled on aircraft 02 bottle?
Answer:
"Aviators Breathing Oxygen" in white 1 inch letters
Question 15: An APU is usually rotated during start by?
Answer:
an electric starter.
Question 16: System in un-psi'd aircraft?
Answer:
continuous flow and pressure demand types
Question 17: Pressure test with water is called?
Answer:
Test to verify serviceability of 02 cylinder (Hydro static test)
Question 18: 8000 feet for transport category aircraft?
Answer:
max altitude Question 19: In a high-pressure oxygen system, if the pressure reducer fails, what prevents high-pressure oxygen from entering the system downstream?
Answer:
Pressure relief valve.Question 20: the valve that prevents the cabin altitude from becoming higher that airplane altitude?
Answer:
negative pressure valve
Question 21: Fuel scheduling during APU start and under varying pneumatic bleed and electrical loads is maintained?
Answer:
automatically by the APU fuel control system.Question 22: To be eligible for recharging, a DOT 3HT oxygen cylinder must have been hydrostatically tested every three years and be retired from service after?
Answer:
24 years or 4,380 filling cycles.
Question 23: to pressurize an A/C on the ground it must be in?
Answer:
air mode
Question 24: what is the ATA for oxygen?
Answer:
35 Question 25: In the diluter demand oxygen regulator, when does the demand valve operate?
Answer:
When the user breathes.Question 26: For use in pressurized aircraft, which is generally the least complicated and requires the least maintenance?
Answer:
Chemical oxygen generator systems.Question 27: What is used in some oxygen systems to change high cylinder pressure to low system pressure?
Answer:
Pressure reducer valve.
Question 28: High storage capacity & low mtc?
Answer:
Chemical 02 advantages