PDF Download
FREE RADIOLOGY AND STUDY GAMES ABOUT MRI
REGISTRY EXAM QUESTIONS
Actual Qs and Ans Expert-Verified Explanation
This Exam contains:
-Guarantee passing score -113 Questions and Answers -format set of multiple-choice -Expert-Verified Explanation
Question 1: Removal of signal from vessels
Answer:
Spatial pre-saturation
Question 2: Small FOV
Answer:
Decreases SNR, increases spatial resolution, no effect on skin time
Question 3: Transmit gain
Answer:
Evaluate accuracy of flip angles
Question 4: Active shielding
Answer:
Superconducting windings in the MRI scanner ( reduce fringe Field)
Question 5: Nerve V
Answer:
Trigeminal
Question 6: High NEX value
Answer:
Increases spatial resolution, increases scan time, increases SNR Question 7: Tissues with a_____are bright on T1 and tissues with a______are bright on T2
Answer:
Short; long
Question 8: Increasing the echo train length
Answer:
Increases chances of blur
Question 9: Pixel size equation for phase and frequency matrix multiplied =
Answer:
Pixel area (answer in MM squared)
Question 10: FOV/phase & FOV/frequency =
Answer:
Pixel size (answer in A x B format)
Question 11: Nerve XI
Answer:
spinal accessory
Question 12: QC test for low contrast spatial resolution
Answer:
Circular image. Should be able to visualize 10 spokes
Question 13: Acquiring half of data in the phase direction
Answer:
Half forurier or zero fill
Question 14: Transmit bandwidth can affect
Answer:
Slice thickness, spatial resolution, SNR
Question 15: Narrow bandwidth
Answer:
Increases SNR, increases spatial resolution, increases scan time, increases chemical shift
Question 16: The sagittal dural sinuses drain into the
Answer:
Internal jugular vein
Question 17: Artifacts that occur in the phase direction
Answer:
Motion, ghosting, zipper, parallel imaging, alaising
Question 18: Thick slices
Answer:
Increase SNR, decreased spatial resolution
Question 19: The first image of the human thorax was in the year
Answer:
1977 (By the Damadian and team)
Question 20: Large FOV
Answer:
Decreases spatial resolution, increases SNR, no affect on scan time
Question 21: Echo planer imaging sequences
Answer:
Are more at risk for TVMF effects
Question 22: The two best planes for TOF of the subclavian artery's are
Answer:
Axial and sagittal
Question 23: Low NEX value
Answer:
Decreases spatial resolution decreases scan time decreases SNR, increases motion artifact Question 24: During dynamic contrast enhanced imaging for vasculature, Cay spaces filled_______to ensure well visualized contrast
Answer:
Centrically Question 25: Best plane for the ovaries is____and to the best plane for the uterus is_____
Answer:
Coronel; sagittal
Question 26: Decreasing the field of view by two
Answer:
Decreases voxel volume by four
Question 27: TR x phase matrix x NEX =
Answer:
Spin echo scan time Question 28: Discovered to DNMR, Fourier transform, and phase and frequency gradients
Answer:
Ernst