- Which type of refrigerant is most commonly used in light commercial
HVAC systems today?
A. R-22
B. R-410A
- R-134a
D. R-12
R-410A is widely used in modern light commercial HVAC systems due to its efficiency and lower ozone depletion potential compared to R- 22.
- What is the purpose of a TXV (Thermostatic Expansion Valve) in a
refrigeration system? 1 / 4
- Increase compressor efficiency
- Regulate the flow of refrigerant into the evaporator
- Reduce condenser pressure
- Heat the air in winter
A TXV controls refrigerant flow to the evaporator to ensure proper superheat and efficient heat transfer.
3. In a direct expansion (DX) cooling system, the evaporator is located:
- After the condenser
- Inside the air handler
- In the compressor
- Outside the building
- What is the primary purpose of a condenser in an HVAC system?
- Cool the air
- Increase refrigerant pressure
- Reject heat from the refrigerant to the environment
- Filter indoor air
- Which type of compressor is commonly used in light commercial
- Scroll 2 / 4
The DX evaporator is inside the air handler or indoor unit, where it absorbs heat from the conditioned air.
The condenser removes heat from the refrigerant, allowing it to condense from a gas to a liquid.
rooftop units?
- Reciprocating
- Screw
- Scroll
- What is the typical pressure range for a medium-temperature R-410A
- 10-50 psi
- 60-100 psi
- 110-145 psi
- 200-250 psi
- What is superheat in a refrigeration system?
- The temperature of refrigerant in the condenser
- The heat added to the compressor
- The temperature of refrigerant vapor above its saturation
- The difference between ambient air and return air
- Which safety device protects the compressor from overpressure in the
Scroll compressors are preferred for light commercial systems due to their reliability, efficiency, and low vibration.
system evaporator?
R-410A operates at higher pressures than older refrigerants; medium-temperature evaporators usually run around 110-145 psi.
temperature
Superheat is measured at the evaporator outlet to ensure no liquid refrigerant enters the compressor.
discharge line? 3 / 4
- Low-pressure switch
- High-pressure switch
C. TXV
- Expansion valve
- Which airflow problem can cause icing on the evaporator coil?
- Low refrigerant charge
- Restricted airflow
- Dirty condenser coil
- High outdoor temperature
- In light commercial HVAC, what is the main function of a
- Reduce refrigerant pressure
- Use outside air for free cooling when conditions allow
- Increase indoor humidity
- Protect compressors
- What is the typical efficiency rating used for light commercial
- / 4
A high-pressure switch shuts off the compressor if discharge pressure exceeds safe limits, preventing damage.
Restricted airflow reduces heat transfer at the evaporator, causing the coil to drop below freezing and ice to form.
economizer?
Economizers reduce energy costs by using cool outside air to assist or replace mechanical cooling.
rooftop units?