CA D73 Structural Wood Panel Installation Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf
- What is the most common thickness for plywood used in floor
- 1/4 inch
- 1/2 inch
- 3/4 inch
- 1 inch
sheathing?
Rationale: Floor sheathing typically requires 3/4-inch plywood to
provide adequate strength and prevent deflection under load.
- When installing structural wood panels, what is the recommended
- 4 inches
- 6 inches
- 8 inches
- 12 inches
spacing for nails along panel edges?
Rationale: Nails along panel edges should be spaced 6 inches apart to
ensure proper attachment and load distribution.
- What is the correct end joint spacing for plywood panels?
- Tight fit with no gap
- 1/8 inch gap
- 1/4 inch gap
- 1/2 inch gap 1 / 3
Rationale: A 1/8-inch gap allows for panel expansion due to moisture
without causing buckling.
- Which type of adhesive is commonly used in structural wood panel
- White glue
- Epoxy
- Construction adhesive
- Polyurethane glue
installation?
Rationale: Construction adhesive provides a strong bond between
panels and framing for structural applications.
- When installing panels on a floor, which direction should the panel face
- Perpendicular to floor joists
- Parallel to floor joists
- Diagonal to floor joists
- Random direction
grain run?
Rationale: Perpendicular orientation maximizes load-carrying
capacity and reduces deflection.
- Which fastener type is preferred for exterior structural panels?
- Wire nails
- Ring-shank nails
- Staples
- Screws without coating
Rationale: Ring-shank nails provide superior holding power,
especially in exterior applications.
- What is the maximum span for 3/4-inch plywood used in floor
- 24 inches
- 32 inches
- 48 inches
- 60 inches
applications with joists spaced 16 inches on center?
Rationale: 3/4-inch plywood can span up to 48 inches between
supports when used for floor sheathing.
- When installing panels on a roof, what is the typical spacing for nails
- 4 inches
- 6 inches 2 / 3
along the field of the panel?
- 8 inches
- 12 inches
Rationale: Nails in the field of roof panels are spaced 8 inches apart
for proper load distribution.
- Which panel grade is suitable for structural applications in wet
- C-D interior
- Exterior-grade plywood
- A-B interior
- Particleboard
environments?
Rationale: Exterior-grade plywood is manufactured with waterproof
adhesives, making it suitable for wet conditions.
- What is the primary purpose of using an underlayment beneath
- Decorative appearance
- Moisture barrier
- Reduce cost
- Increase thickness
structural panels?
Rationale: Underlayment protects the structural panels from moisture
intrusion, enhancing longevity.
- Which tool is most appropriate for cutting large structural wood
- Hand saw
- Jigsaw
- Circular saw
- Chisel
panels?
Rationale: Circular saws provide straight, clean cuts and are efficient
for cutting large panels.
- What is the minimum thickness of OSB used for wall sheathing?
- 1/4 inch
- 7/16 inch
- 1/2 inch
- 3/4 inch
Rationale: 7/16-inch OSB is standard for wall sheathing to provide
structural support without excessive weight.
- How should panels be staggered when installed on floors or
- / 3
walls?