Journeyman Plumber Licensing Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the minimum slope required for a 3-inch horizontal drain line?
- 1/8 inch per foot
- 1/4 inch per foot
- 3/8 inch per foot
- 1/2 inch per foot
Rationale: Plumbing codes require a minimum slope of 1/4 inch per foot
for 2 1/2-inch through 3-inch pipes to ensure proper drainage velocity.
- The maximum developed length of a 1/2-inch water supply line to a
- 30 feet
- 50 feet 1 / 4
fixture should not exceed how many feet before upsizing is required?
- 75 feet
- 100 feet
Rationale: Pressure loss limits for 1/2-inch lines are typically around 50
feet; beyond this, upsizing prevents insufficient flow.
3. The purpose of a vent system in a plumbing installation is to:
- Prevent freezing of the system
- Provide water for traps
- Equalize air pressure and prevent trap siphonage
- Drain rainwater
Rationale: Vents equalize air pressure in the drainage system, maintaining
trap seals and preventing siphonage.
- Which type of pipe is most commonly used for natural gas distribution?
A. PVC
B. CPVC
- Black steel
- Copper
Rationale: Black steel pipe is the standard material for natural gas piping
due to strength and compatibility.
- / 4
- The minimum air gap for a fixture outlet above the flood-level rim of a
receptor shall be:
- One pipe diameter
- Two pipe diameters
- Three pipe diameters
- Four pipe diameters
Rationale: Codes specify a minimum air gap of two pipe diameters to
prevent backflow contamination.
- What is the minimum trap diameter required for a kitchen sink?
- 1 inch
- 1 1/4 inches
- 1 1/2 inches
- 2 inches
Rationale: Kitchen sinks require 1 1/2-inch traps to handle grease and
solids without clogging.
- What is the primary function of a cleanout fitting?
- To test system pressure
- To allow access for drain cleaning
- To provide venting
- To trap debris 3 / 4
Rationale: Cleanouts allow access for mechanical cleaning of drainage
pipes.
- The minimum distance between a water closet and a side wall (center to
wall) is:
- 10 inches
- 15 inches
- 18 inches
- 24 inches
Rationale: The plumbing code requires at least 15 inches from the
centerline of a water closet to the nearest obstruction.
- What is the standard water pressure range for most residential systems?
- 10–30 psi
- 40–80 psi
- 90–120 psi
- 130–150 psi
Rationale: The typical safe and functional residential water pressure range
is 40–80 psi.
10. A trap seal depth should be between:
- 1/2 inch and 1 inch
- / 4