What is the minimum size of a trap arm for a water closet? 1.
- 2 inches
- 3 inches
- 4 inches
- 1½ inches
Rationale: Water closets require a minimum 3-inch trap arm to properly
handle waste discharge and prevent clogging.
The main purpose of a plumbing vent is to: 2.
- Provide water to fixtures
- Equalize air pressure in the drainage system
- Stop sewer gas leaks
- Increase water flow 1 / 4
Rationale: Vents prevent negative pressure that could siphon traps and
allow smooth waste flow.
What type of fitting is used to connect two pipes of different sizes in a 3.straight line?
- Elbow
- Reducer coupling
- Cross
- Wye
Rationale: A reducer coupling transitions between different pipe diameters
while maintaining alignment.
The minimum slope for a 3-inch horizontal drainage pipe is: 4.
- ¼ inch per foot
- ⅛ inch per foot
- ½ inch per foot
- 1 inch per foot
Rationale: ⅛ inch per foot is sufficient for 3-inch or larger pipes to maintain flow without excessive velocity.
A plumbing trap must: 5.
- Be vented on the outlet side only 2 / 4
- Hold at least 4 inches of water
- Seal against sewer gases
- Be installed vertically
Rationale: The trap’s water seal blocks sewer gases from entering living
spaces.
What type of valve is commonly used on gas lines? 6.
- Gate valve
- Globe valve
- Ball valve
- Check valve
Rationale: Ball valves allow quick shutoff and are suitable for gas line
safety.
A water heater’s temperature relief valve must discharge: 7.
- Into a vent stack
- Into a floor drain
- Onto the floor
- To an approved discharge location by gravity
Rationale: T&P valves must safely discharge by gravity to prevent scalding
or pressure buildup.
- / 4
Which of the following materials is approved for underground drainage 8.piping?
- Galvanized steel
- PVC (Schedule 40)
- Copper DWV
- Lead
Rationale: PVC Schedule 40 is corrosion-resistant and widely approved for
underground use.
The maximum trap seal depth allowed by code is typically: 9.
- ½ inch
- 1 inch
- 4 inches
- 6 inches
Rationale: Excessive trap seal depth can slow drainage and lead to
siphonage.
What is the minimum distance between a cleanout and the wall it faces? 10.
- 6 inches
- 12 inches
- 18 inches
- 24 inches
- / 4