Master Electrician Licensing Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the maximum allowable voltage drop for a feeder circuit to
- 1%
- 3%
- 5%
ensure efficient operation?
D) 10%
Rationale: NEC recommends a maximum of 5% voltage drop for
feeders and branch circuits to maintain equipment efficiency and prevent overheating.
- Which conductor is typically used as a grounding conductor?
- Black
- White
- Green or bare copper 1 / 4
- Red
Rationale: Green or bare copper wires are designated for grounding to
provide a safe path for fault current.
- According to the NEC, how often should arc-fault circuit interrupters
- Only in kitchens
- Only in living rooms
- In all bedrooms
- Only in garages
(AFCIs) be installed in dwelling unit bedrooms?
Rationale: NEC 210.12 requires AFCIs in all dwelling unit bedrooms to
reduce fire risk from arc faults.
- What is the maximum ampacity of a 12 AWG copper conductor in a
residential application under normal conditions?
A) 10A
B) 15A
C) 20A
D) 25A
Rationale: According to NEC Table 310.15(B)(16), 12 AWG copper
conductors are rated for 20 amps.
- Which device protects against overcurrent caused by short circuits or
- Transformer
- Circuit breaker 2 / 4
overloads?
- Contactor
- Surge protector
Rationale: Circuit breakers are designed to interrupt current in
overload or short circuit conditions to prevent damage and fire hazards.
- What is the purpose of a GFCI outlet?
- Increase voltage
- Prevent electrocution
- Reduce energy consumption
- Stabilize current
Rationale: Ground-Fault Circuit Interrupters (GFCI) detect current
leakage and trip to prevent shock hazards.
- What type of conduit is typically used outdoors and underground?
A) EMT
B) PVC
- Flexible metal conduit
- BX cable
Rationale: PVC conduit is corrosion-resistant and suitable for wet and
underground locations.
- How many wires are required in a 120/240V single-phase branch
- 2
circuit with a neutral?
B) 3 3 / 4
- 3 hot/neutral/ground
- 4
Rationale: A single-phase 120/240V circuit requires two hot wires, one
neutral, and typically a ground.
- What is the minimum burial depth for rigid metal conduit (RMC) under
- 12 inches
- 18 inches
- 24 inches
- 6 inches
residential driveways?
Rationale: NEC Table 300.5 specifies 6 inches minimum burial depth
for RMC under concrete driveways.
- Which type of load is considered continuous under NEC?
- Loads lasting less than 1 hour
- Loads fluctuating rapidly
- Loads expected to run for 3 hours or more
- Motor loads only
Rationale: NEC defines continuous load as a load expected to operate
for three hours or more.
- What color is typically used for a grounded (neutral) conductor?
- Black
- Red
- White
- / 4