• wonderlic tests
  • EXAM REVIEW
  • NCCCO Examination
  • Summary
  • Class notes
  • QUESTIONS & ANSWERS
  • NCLEX EXAM
  • Exam (elaborations)
  • Study guide
  • Latest nclex materials
  • HESI EXAMS
  • EXAMS AND CERTIFICATIONS
  • HESI ENTRANCE EXAM
  • ATI EXAM
  • NR AND NUR Exams
  • Gizmos
  • PORTAGE LEARNING
  • Ihuman Case Study
  • LETRS
  • NURS EXAM
  • NSG Exam
  • Testbanks
  • Vsim
  • Latest WGU
  • AQA PAPERS AND MARK SCHEME
  • DMV
  • WGU EXAM
  • exam bundles
  • Study Material
  • Study Notes
  • Test Prep

Master Gas Fitter Licensing Exam

Class notes Jan 2, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

Master Gas Fitter Licensing Exam Practice Test Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf

  • A Master Gas Fitter is primarily responsible for which of the following?
  • Installing only residential gas systems
  • Supervising and ensuring code compliance of gas installations
  • Writing gas utility policies
  • Designing HVAC system ductwork
  • B Ensuring compliance and supervision of technicians is the key legal responsibility of a Master Gas Fitter.

  • The maximum pressure allowed in a low-pressure natural gas
  • distribution system inside a building is typically: 1 / 3

  • 2 psi
  • 0.5 psi (14 inches WC)
  • 5 psi
  • 125 psi
  • Low-pressure systems are defined at 14" water column or lower.

  • Which pipe material is approved for underground natural gas service
  • lines?

  • Copper Type M
  • Polyethylene (PE)
  • PVC Schedule 40
  • Galvanized steel
  • PE piping is standard for underground gas distribution due to corrosion resistance.

  • What is the main reason drip legs are installed?
  • To reduce noise
  • To collect condensate and debris
  • Increase pressure
  • Provide pressure relief
  • Condensation and debris must be trapped before appliances.

  • The primary combustion air source must provide at least how many
  • cubic feet per 1,000 BTU/hr of appliance input?

  • 20 cu.ft
  • 50 cu.ft 2 / 3
  • 75 cu.ft
  • 100 cu.ft

Standard rule: 50 cu.ft of air per 1,000 BTU/hr for proper combustion.

6. Excess flow valves are used to:

  • Reduce gas odor
  • Increase pressure for appliances
  • Stop uncontrolled gas flow due to line break
  • Control humidity
  • They protect against rupture-induced gas discharge.

7. An appliance regulator is required when inlet supply pressure exceeds:

  • 7" WC
  • 14" WC
  • 1 psi
  • 2 psi
  • Above low pressure requires a regulator to maintain safe appliance inlet pressure.

8. Purging a gas line should be done:

  • Into a closed container
  • To a safe outdoor location with ignition sources eliminated
  • Into the sewer
  • Inside mechanical room
  • Gas must be vented safely to atmosphere away from hazards.

  • / 3

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

I was amazed by the practical examples in this document. It was a perfect resource for my project. Truly remarkable!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 2, 2026
Description:

Master Gas Fitter Licensing Exam Practice Test Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf 1. A Master Gas Fitter is primarily responsible for w...

Unlock Now
$ 1.00