Master Plumber Licensing Exam

Class notes Jan 2, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

Master Plumber Licensing Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf

  • The minimum size of a building drain shall not be less than
  • 2 inches
  • 3 inches
  • 4 inches
  • 1½ inches

Rationale: The code requires a minimum 3-inch drain for a single-

family dwelling to handle combined discharge loads.

  • A vent pipe must be installed to prevent
  • Water pressure loss
  • Air infiltration
  • Trap seal siphonage
  • Pipe corrosion 1 / 4

Rationale: Vents allow air into the drainage system to prevent

siphonage and maintain trap seals.

  • The minimum slope for a 4-inch horizontal drainage pipe is
  • 1/8 inch per foot
  • 1/4 inch per foot
  • 1/2 inch per foot
  • Level

Rationale: A 1/4 inch per foot slope ensures proper flow and prevents

solids from settling.

  • The main vent stack shall extend through the roof not less than
  • 4 inches above the roof
  • 6 inches above the roof
  • 8 inches above the roof
  • 10 inches above the roof

Rationale: Minimum extension above the roof prevents snow or

debris from blocking the vent.

  • The maximum distance between a trap and its vent for a 2-inch trap
  • arm is

  • 2 feet
  • 3 feet
  • 5 feet
  • 8 feet 2 / 4

Rationale: Trap arm length is limited by pipe diameter to prevent

siphonage due to pressure drop.

  • The water service pipe must be buried not less than
  • 12 inches below frost line
  • 6 inches below grade
  • 8 inches below grade
  • 10 inches below grade

Rationale: Burial below frost line prevents freezing and pipe rupture.

  • The minimum trap seal depth is
  • 1 inch
  • 1½ inches
  • 2 inches
  • 3 inches

Rationale: A 2-inch trap seal prevents sewer gases from entering the

building.

  • The minimum size of a water closet branch drain is
  • 2 inches
  • 2½ inches
  • 3 inches
  • 4 inches

Rationale: Water closets require a 3-inch drain to handle discharge

volume. 3 / 4

  • The proper method to test a water supply system is
  • Smoke test
  • Hydrostatic pressure test
  • Air test
  • Flow test

Rationale: Hydrostatic testing ensures water-tightness under

operational pressure.

  • Backflow prevention is required to prevent
  • Air infiltration
  • Contamination of potable water
  • Pressure surges
  • Leakage

Rationale: Backflow devices stop contaminated water from entering

the potable system.

  • The minimum vertical distance between a water supply outlet
  • and the flood level rim is

  • 1 inch
  • 2 inches
  • 1 inch above flood level rim
  • 3 inches
  • Rationale: Air gaps prevent cross-connection and back-siphonage.

  • / 4

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

This document provided in-depth analysis, which made learning easy. Absolutely excellent!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 2, 2026
Description:

Master Plumber Licensing Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf 1. The minimum size of a building drain shall not be less tha...

Unlock Now
$ 1.00