NATE Air Distribution Test (Latest Update 2026 / 2027) Questions with Correct Answers | Grade A

Question:

How many holes must be made in a round duct in order to take a series of traverse readings?

Answer:

Two

Question:

A thermo-anemometer measures

Answer:

FPM directly

Question:

Dehumidification occurs when an air conditioning coil

Answer:

Operates at or below the dew point of the air moving across it 1 / 4

Question:

Who usually determines if a duct leakage test is to be performed and the test pressure at which it will be performed?

Answer:

The design engineer

Question:

When the dry bulb temperature increases, the relativity humidity of air

Answer:

Decreases

Question:

When the dry bulb temperature increases, the specific volume of the air

Answer:

Increases

Question:

When the dry bulb temperature increases, the density of air

Answer:

Decreases 2 / 4

Question:

The cfm per ton rate for normal comfort cooling is approximately

Answer:

400 CFM per Ton

Question:

Cooling air raises its

Answer:

Relative humidity

Question:

Air with a dry bulb temperature of 60 degrees and a wet bulb temperature of 60 degrees has a relative humidity of

Answer:

100%

Question:

Air with a dry bulb temperature of 60 degrees and a wet bulb temperature of 60 degrees has a dew point temperature of

Answer:

70 degrees 3 / 4

Question:

Return air grilles are not to be installed in

Answer:

Bathrooms or kitchens

Question:

The proper amount of air in CFM for each room is determined by

Answer:

A detailed room-by-room heat load calculation

Question:

On residential duct installations the accepted method of attaching duct sections to each other is?

Answer:

Using the slip and drive method

Question:

Which of the following is not an acceptable location for a thermostat?

Answer:

Five feet off the floor on an outside wall

  • / 4

User Reviews

★★★★★ (5.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★★

This document provided practical examples, which was incredibly useful for my research. Absolutely remarkable!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: QUESTIONS & ANSWERS
Added: Dec 16, 2025
Description:

NATE Air Distribution Test (Latest Update) Questions with Correct Answers | Grade A Question: How many holes must be made in a round duct in order to take a series of traverse readings? Answer: Two...

Unlock Now
$ 1.00