FDNY G40 Use Of Liquefied Petroleum Gas Or Compressed Natural Gas For Tar Kettles Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the primary purpose of the FDNY G40 certificate?
- To allow transporting gasoline for construction equipment
- To authorize operation of tar kettles using propane or CNG
- To inspect building gas systems
- To install gas piping
- To authorize operation of tar kettles using propane or CNG
This certificate specifically regulates the safety procedures for LPG or CNG-powered tar kettles.
2. LPG cylinders must be stored:
- Inside the tar kettle
- Horizontally near the burner
- Upright, secured from falling 1 / 4
- On their side
- Upright, secured from falling
- What is the required distance between LPG cylinders and open
- 5 feet
- 10 feet
- 20 feet
- 3 feet
- 20 feet
- The maximum allowable size of an LPG cylinder used with tar kettles is
Vertical storage with securing prevents rolling and valve damage.
flames?
FDNY safety rules require a 20-ft separation to prevent ignition risk.
typically:
- 5 lbs
- 20 lbs
- 100 lbs
- 420 lbs
- 100 lbs
- What document must be kept on-site during LPG tar kettle operation?
- Corporate tax number
- Worker identification cards 2 / 4
Tar kettle operations normally use cylinders up to 100 lbs for proper supply and control.
- FDNY certificate card
- Commercial insurance certificate
- FDNY certificate card
- A tar kettle using LPG must be located at least how far from any
- 5 feet
- 10 feet
- 15 feet
- 25 feet
- 25 feet
The operator must present the certification upon inspection.
building opening?
To prevent vapor entry into a structure, a 25-ft clearance distance is required.
7. If a gas leak is suspected, the operator must FIRST:
- Strike a match
- Continue working
- Check the valve with a lighter
- Shut off the gas supply
- Shut off the gas supply
- Which fire extinguisher type is required at tar kettle sites?
- Class D 3 / 4
Immediate emergency response is stopping fuel flow to prevent ignition.
- Class B
- Class A only
- CO₂ only
- Class B
- What must be done when transporting LPG cylinders?
- Roll them on the ground
- Store them horizontally
- Leave valve caps off
- Install valve protection caps
- Install valve protection caps
Class B extinguishers are required due to presence of flammable liquids and gases.
Valve protection prevents accidental damage and leaks.
10. Tar kettle temperature must be monitored:
- By hand touching
- By thermometer or gauge
- By visual guesswork
- Using burner color
- By thermometer or gauge
Accurate heat measurement prevents overheating and flash ignition.
11. When not in use, LPG cylinder valves must be:
- Fully open
- Slightly open
- / 4