Practice Exam Questions And Correct

Class notes Jan 1, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

ASSE 6030 Medical Gas Systems Verifier Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf

  • Which organization establishes the qualifications for medical gas verifiers
  • under the ASSE 6000 series?

A. NFPA

B. ANSI

  • ASSE International

D. OSHA

Rationale: ASSE International develops and maintains the ASSE 6000 series

professional qualification standards for medical gas personnel.

  • / 4

2. The ASSE 6030 verifier is responsible for:

  • Designing the medical gas system
  • Verifying the installation and performance of the system
  • Maintaining the system daily
  • Certifying the installer

Rationale: The verifier ensures the system is installed per NFPA 99 and

performs functional verification testing.

  • What is the primary standard governing medical gas systems in healthcare
  • facilities?

A. ASME B31.1

B. NFPA 99

C. NFPA 101

D. ASSE 6000

Rationale: NFPA 99 outlines requirements for the design, installation, and

verification of medical gas and vacuum systems.

4. According to NFPA 99, the verifier shall be independent of:

  • The facility’s maintenance team only
  • The manufacturer only
  • The installer and manufacturer
  • The AHJ 2 / 4

Rationale: The verifier must be independent to ensure unbiased

verification results.

5. The final verification report must be submitted to:

  • The installing contractor
  • The facility’s responsible authority or owner
  • The gas supplier
  • The design engineer

Rationale: The owner or responsible authority receives the official

verification documentation.

  • Which document must the verifier review before beginning verification
  • testing?

  • Maintenance schedule
  • Equipment warranty
  • Installer’s certification documents and as-built drawings
  • Owner’s manual

Rationale: Verification is based on installed conditions and system

drawings to confirm compliance.

  • What is the required purity for medical oxygen in the pipeline system?

A. 90% 3 / 4

B. 93%

  • 99.0% minimum

D. 99.9%

Rationale: Medical oxygen must meet the U.S. Pharmacopeia (USP)

requirement of not less than 99.0% purity.

  • Which of the following gases is classified as nonflammable and oxidizing?
  • Nitrogen
  • Oxygen
  • Carbon dioxide
  • Nitrous oxide

Rationale: Oxygen supports combustion and is classified as an oxidizer,

though not flammable.

  • Vacuum systems for patient use must maintain a minimum flow rate per

NFPA 99 of:

  • 2.5 scfm per station
  • 3.5 scfm per station
  • 5.0 scfm per station
  • 10 scfm per station

Rationale: The required flow rate for patient vacuum outlets is 3.5 scfm at

12 inHg minimum.

  • / 4

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

The detailed explanations offered by this document made learning easy. A impressive purchase!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 1, 2026
Description:

ASSE 6030 Medical Gas Systems Verifier Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf 1. Which organization establishes the qualifica...

Unlock Now
$ 1.00