Certified Elevator Inspector (CEI) Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the primary purpose of a car top inspection?
- To check fire safety systems
- To verify elevator cab aesthetics
- To ensure mechanical and electrical components are safe
- To inspect passenger behavior
Rationale: Car top inspections focus on mechanical and electrical
components to ensure safety and proper operation.
- Which component prevents the elevator car from falling in case of
- Governor rope 1 / 4
overspeed?
- Safety gear
- Counterweight
- Hoistway door
Rationale: The safety gear engages when an elevator exceeds its rated
speed to stop the car safely.
3. The ANSI/ASME A17.1 code primarily governs:
- Fire alarm systems
- Electrical wiring of buildings
- Elevator and escalator safety
- Occupational safety
Rationale: ANSI/ASME A17.1 sets safety standards for elevators,
escalators, and related conveyances.
- What is the minimum clearance required between the car top and
- 6 inches
- 42 inches
- 24 inches
- 60 inches
hoistway ceiling?
Rationale: A minimum of 42 inches is required for safety during car top
inspections and maintenance access.
- Which device protects an elevator from excessive electrical current?
- Transformer 2 / 4
- Contactor
- Overcurrent protection device
- Brake resistor
Rationale: Overcurrent protection devices like fuses or circuit breakers
prevent damage and fire from electrical overloads.
- Which of the following is a primary requirement for machine room
- Keyless entry
- Restricted access to authorized personnel
- Visibility from lobby
- Automatic door lock
access?
Rationale: Safety codes require that only qualified personnel can access
the machine room to reduce risk of injury.
7. The pit of an elevator must be capable of supporting:
- Only the car weight
- Car, counterweight, and buffer impact loads
- Just the counterweight
- Passengers only
Rationale: The pit structure must support all dynamic and static loads to
ensure safety during operation and emergencies.
- What is the main function of a governor in an elevator system?
- Control door operations 3 / 4
- Activate lighting
- Detect overspeed and trigger safety gear
- Balance the counterweight
Rationale: The governor monitors car speed and activates the safety gear
if the elevator exceeds rated speed.
9. Elevator car doors are required to reopen if:
- The alarm sounds
- An obstruction is detected
- The motor overheats
- The car reaches top floor
Rationale: Door reopening systems prevent injury or entrapment when an
object blocks the doorway.
- How often must hydraulic elevators be inspected according to ASME
A17.1?
- Every 6 months
- Every 5 years
- Every 12 months
- Every 24 months
Rationale: Hydraulic elevators require annual inspections to ensure
operational and safety compliance.
- Which of the following is true about emergency stop switches?
- They stop the elevator gradually
- / 4