BICSI Installer 2 Copper Certification Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
(Covers Installation Requirements, Copper Media, Testing, Standards, Safety, and Troubleshooting)
- What is the primary function of a horizontal cross-connect (HC)?
- To connect backbone cables to work area outlets
- To connect horizontal cabling to backbone cabling
- To terminate patch cords in the equipment room
- To manage optical fiber connections
Rationale: The horizontal cross-connect links horizontal cabling to the
backbone cabling, forming part of the structured cabling system per ANSI/TIA-568 standards._
- / 4
2. The maximum allowable length for a horizontal copper cable is:
- 90 meters including patch cords
- 95 meters total length
- 90 meters for permanent link, plus 10 meters for patch cords
- 100 meters for cable only
Rationale: TIA-568 specifies a 100-meter channel—90 meters for
permanent link and 10 meters for patch cords._
- What tool is used to ensure pairs are not split during termination?
- Tone generator
- Wire map tester
C. OTDR
- Cable stripper
Rationale: Wire map testers verify correct pair terminations, ensuring no
splits or miswires._
- Which copper category supports 10GBASE-T up to 100 meters?
- Category 5e
- Category 6
- Category 6A
- Category 7
Rationale: Category 6A (Augmented Cat 6) supports 10GBASE-T Ethernet
up to 100 meters._ 2 / 4
- What is the purpose of color coding in 110 blocks?
- For decorative purposes
- To identify pairs and ensure correct wiring sequences
- To improve signal transmission
- To reduce crosstalk
Rationale: Color codes ensure correct T568A or T568B pair terminations._
6. The T568A and T568B standards differ in:
- Cable length
- Pair-to-pin assignments
- Impedance
- Wire gauge
Rationale: The only difference between T568A and T568B is the pair-to-pin
configuration on the connector._
- What is NEXT in copper testing?
- Noise from external sources
- Crosstalk measured at the same end as the signal source
- Return loss
- Attenuation between ends 3 / 4
Rationale: Near-End Crosstalk (NEXT) measures interference at the
transmitting end._
- What should be done before pulling copper cables into a conduit?
- Apply grease to the cable
- Inspect conduit for damage and obstructions
- Preload conduit with other cables
- Twist cables tightly together
Rationale: Inspecting the conduit ensures no damage that could harm the
cable during pulling._
- Which type of cable is most common for LAN horizontal cabling?
- Coaxial
B. UTP
C. STP
- Twinax
Rationale: Unshielded Twisted Pair (UTP) is the most widely used copper
cable for LAN horizontal cabling._
- What is the maximum untwist length allowed for a twisted pair at a
- 1 inch
- / 4
termination?