BICSI Registered Communications Distribution Designer (RCDD) Certification Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the primary role of an RCDD in a telecommunications project?
- To terminate fiber optic cables
- To design and integrate structured cabling systems
- To supervise equipment installation
- To perform network troubleshooting
Rationale: The RCDD’s main role is designing and integrating
communications infrastructure systems, not hands-on installation or troubleshooting.
- What document defines the client’s requirements and scope of work?
- Request for Information (RFI)
- Request for Proposal (RFP) 1 / 4
- Shop drawings
- As-built drawings
Rationale: The RFP outlines the project’s scope, technical specifications,
and requirements for proposals.
- Which standard provides guidelines for telecommunications cabling
infrastructure within commercial buildings?
A. IEEE 802.3
- ANSI/TIA-568 series
C. ISO 9001
- NEC Article 250
Rationale: The ANSI/TIA-568 standard defines requirements for structured
cabling systems.
- What is the maximum horizontal cable length in a structured cabling
- 80 meters
- 85 meters
- 90 meters
- 100 meters
system according to ANSI/TIA-568?
Rationale: The standard allows 90 meters of horizontal cable plus 10
meters for patch cords and jumpers, totaling 100 meters. 2 / 4
- What is the primary function of a telecommunications room (TR)?
- Housing building power panels
- Termination and cross-connection of horizontal cabling
- Storing servers
- Managing HVAC systems
Rationale: The TR is dedicated to telecommunications equipment and cable
terminations.
- What is the recommended maximum distance between grounding
- 10 meters
- 30 meters
- 50 meters
- 100 meters
electrodes in a telecommunications bonding backbone?
Rationale: Telecommunications bonding conductors should be bonded at
intervals not exceeding 30 meters per ANSI/TIA-607.
- What type of cable is typically used for backbone cabling between
buildings?
A. UTP
- Fiber optic cable 3 / 4
- Coaxial cable
- Shielded twisted pair
Rationale: Fiber optic cables are preferred for backbone cabling due to
long-distance capability and high bandwidth.
- What is the primary concern when designing a telecommunications
- Cable routing
- Safety and signal reference integrity
- Equipment color coding
- Power supply redundancy
grounding system?
Rationale: Grounding ensures personnel safety and minimizes signal
interference by maintaining reference potential.
- Which area in a building typically houses backbone terminations, cross-
- Work area
- Telecommunications room
- Equipment room
- Entrance facility
connects, and sometimes routers or switches?
Rationale: The equipment room contains backbone and active network
devices; it’s distinct from TRs.
- / 4