FDNY S86 Certificate of Fitness for Professional Certification of Fire Alarm System Design Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- Which type of fire alarm system is designed to provide signals directly
- Local alarm system
- Proprietary system
- Central station system
- Auxiliary system
to a central station for monitoring?
Rationale: Central station systems transmit signals to a central
monitoring station for immediate response.
- What is the primary purpose of a fire alarm control panel (FACP)?
- To detect smoke
- To receive and process signals from initiating devices and control 1 / 4
notification appliances
- To supply emergency power
- To supervise sprinklers
Rationale: The FACP serves as the hub of the fire alarm system,
managing signals from detectors and activating alarms.
- Which device is primarily used to detect smoke in a fire alarm system?
- Heat detector
- Smoke detector
- Manual pull station
- Horn/strobe
Rationale: Smoke detectors sense smoke particles and trigger the fire
alarm system.
- According to NFPA 72, how often must fire alarm system batteries be
- Monthly
- Annually
- Weekly
- Daily
tested?
Rationale: NFPA 72 requires weekly inspections of batteries to ensure
system readiness.
- What is the main function of a manual pull station?
- Detect heat
- Allow occupants to manually initiate a fire alarm 2 / 4
- Provide emergency lighting
- Monitor sprinklers
Rationale: Manual pull stations let building occupants trigger the
alarm in case of fire.
- Which type of detector is most suitable for a dusty or smoky industrial
- Ionization smoke detector
- Photoelectric smoke detector
- Heat detector
- Carbon monoxide detector
environment?
Rationale: Heat detectors are less sensitive to dust and smoke,
reducing false alarms in industrial settings.
- What does a NAC (Notification Appliance Circuit) control?
- Fire pumps
- Sprinkler valves
- Horns, strobes, and speakers
- Smoke vents
Rationale: NAC circuits supply power and control to notification
devices like horns and strobes.
- Which type of fire alarm system is monitored by the building owner
- Proprietary system
- Central station system 3 / 4
but not connected to a central station?
- Auxiliary system
- Local system
Rationale: Proprietary systems are self-monitored by the building
management.
- In a fire alarm system, what is the purpose of an addressable device?
- To detect only heat
- To provide unique identification and location information to the
- To monitor water flow
- To supply battery backup
FACP
Rationale: Addressable devices communicate their specific location
to the control panel for precise alarm identification.
- What is the minimum sound level required for audible
- 50 dBA
- 70 dBA
- 75 dBA
- 85 dBA
notification appliances in sleeping areas according to NFPA 72?
Rationale: NFPA 72 specifies 75 dBA at the pillow location in sleeping
areas for effective notification.
- Which type of detector responds fastest to flaming fires?
- Ionization smoke detector
- Photoelectric smoke detector
- / 4