- What is the primary reason for extracting landfill gas from a sanitary
- To reduce leachate production
- To prevent methane build-up and reduce greenhouse gas emissions
- To increase waste decomposition speed
- To reduce odors only
landfill rather than allowing it to vent freely into the atmosphere?
Answer: B
Rationale: Methane is a potent greenhouse gas and can accumulate to
explosive concentrations; controlled extraction prevents build-up, mitigates explosion risk, and reduces environmental impact.
- / 4
- Which of the following gas concentrations in landfill gas is most typical
for methane (CH₄)?
A. 5–10%
B. 20–30%
C. 40–60%
D. 70–85%
Answer: C
Rationale: Landfill gas typically consists of roughly 50% methane and 30–
40% carbon dioxide, though composition may vary.
- At what lower explosive limit (LEL) percentage of methane in air does
landfill gas become an explosion hazard?
A. 0.5%
- 5%
C. 15%
D. 25%
Answer: B
Rationale: Methane’s LEL is around 5% by volume in air; concentrations at
or above this can be ignitable if an ignition source is present.
- What is the primary purpose of a flame arrestor in a landfill gas piping
system? 2 / 4
- Increase gas flow rate
- Reduce gas moisture content
- Prevent flame propagation back into the gas well
- Remove hydrogen sulfide (H₂S) from the gas
Answer: C
Rationale: A flame arrestor stops a flame front from traveling backward
through the pipeline into the potentially explosive gas source.
- Which regulatory standard is most likely to govern landfill gas system
- OSHA 1910 Subpart Z
- NFPA 820 – Standard for Fire Protection in Wastewater Treatment and
- NFPA 30 – Flammable and Combustible Liquids Code
- NFPA 54 – National Fuel Gas Code
design and operation under New York City jurisdiction?
Collection Facilities
Answer: B
Rationale: NFPA 820 provides fire and explosion safety guidance pertinent
to waste-handling and gas-handling facilities, including landfill gas operations.
- What is the minimum frequency recommended for monitoring methane
concentrations in enclosed structures near a landfill gas collection system? 3 / 4
- Once a month
- Once a quarter
- Weekly
- Daily
Answer: C
Rationale: Weekly monitoring helps detect dangerous methane
accumulations early, before reaching flammable levels.
- During startup of a blower to extract landfill gas, what should be
- Gas pressure at the flare stack
- Closure of all well-head valves
- Operation of automatic spark-ignition controls
- Moisture removal system functioning
verified first?
Answer: C
Rationale: Automatic ignition control ensures that extracted gas is safely
combusted; verifying this before blower startup prevents unignited gas discharge.
- What is a primary advantage of a vertical gas extraction well over a
- / 4
horizontal collector trench?