Accessibility - CORRECT ANSWER: as defined in NPFA admitting close approach:not gaurded by locked doors, elevation, and other effective means
Addressable System Smoke Detectors - CORRECT ANSWER: Provide an alarm
indication to a control unit. In addition,they also signal the location of the alarm
Alarm Log book - CORRECT ANSWER: an alarm logbook shall be maintained on the
premises, at the buildings main Fre Alarm Control Panel
Alarm log book - CORRECT ANSWER: each section shall have a sufficent number of
pages to allow for entries for at least one year
Alarm Notification Appliance - CORRECT ANSWER: A fire alarm system component,
such as a bell, horn, speaker, light, text display or vibration device that issues an audible, tactile, and/or visual alert
Alarm Signal - CORRECT ANSWER: A signal indicating an emergency requiring
immediate action, such as a signal indicative of fire.
Alarm silence reset switch or button - CORRECT ANSWER: this switch is used to reset the fire alarm condition has been cleared
alarms and detectors - CORRECT ANSWER: should not be painted
Annunciator - CORRECT ANSWER: A unit containing one or more indicator lamps,
alphanumeric displays, or other equivalent means in which each indication provides status information about a circuit, condition or location.
Approved Central Station Company - CORRECT ANSWER: A central station company
that has been issued a valid certificate of operation from FDNY.
ARCS (Auxiliary Radio Communication System) - CORRECT ANSWER: In-Building
Emergency Radio coomunication system. ARC system is a wireless two-way building communication system for fire department use only
Audio and Visual Notification Devices - CORRECT ANSWER: Speaker, speaker
strobe,horn strobe, strobe,Gong bells
- / 2
Building fire protection features- activated by the Fire Alarm System - CORRECT
ANSWER: smoke dampers, fire dampers,elevator recall, door release (where
connected to FACP)
central station - CORRECT ANSWER: A facility that receives alarm signals from a
protected premises and retransmits or otherwise reports such alarm signals to the department
Defined Fire Alarm System - CORRECT ANSWER: A fire alarm system or any sub-
system thereof that automatically transmits signals to the department or a central station and that is installed in premises which are required to have a fire alarm system.
Designated Representative - CORRECT ANSWER: A person or entity designated by
the subscriber who shall be responsible for receiving notifications from the central station company concerning the status of the protective signaling system at the protected premises and who is authorized to take action with respect to such system.
Duct smoke detectors - CORRECT ANSWER: Smoke detectors that sample the air
moving through the air distribution system ductwork or plenum; upon detecting smoke, the detector sends a signal to shut down the air distribution unit, close any associated smoke dampers, or initiate smoke control system operations.
Elevator lobby smoke Detector - CORRECT ANSWER: Are smoke detectors thtat when
activated will recall elevators automatically into the designated landing
Elevator Recall - CORRECT ANSWER: The fire Alarm system integrates with elevator controls to recall elevator cars to a designated landing floor in the event of an alarm
FACP - CORRECT ANSWER:
fire alarm box color - CORRECT ANSWER: red color
Fire Alarm Control Panel (FACP) - CORRECT ANSWER: contains electronics that
control and monitor the fire alarm system.
Fire alarm control unit or panel(FACP,FCS) - CORRECT ANSWER: System component
that receives input from automatic and manual fire alarm devices and may provide power to detection devices or communication devices.
Fire Alarm Signal - CORRECT ANSWER: A signal initiated by a fire alarm-initiating device such as a manual fire alarm box (pull station), automatic fire detector, water-flow switch, or other device whose activation is indicative of the presence of a fire or fire signature.
Fire Alarm system off-line - CORRECT ANSWER: Anytime a fire alarm system is to be activated during a test ,inspection, or fire drill, it is mandatory to take the system "offline"