FDNY P98 Fuel-Oil Piping and Storage System Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the maximum allowable working pressure for standard
- 10 psi
- 15 psi
- 30 psi
- 60 psi
- 15 psi
residential fuel-oil piping?
Rationale: Standard residential fuel-oil piping is designed for low-
pressure systems and should not exceed 15 psi to prevent leaks or ruptures. 1 / 4
- Which material is most commonly used for underground fuel-oil
piping?
a) Copper
b) Steel
c) Polyethylene (PE)
d) PVC
c) Polyethylene (PE)
Rationale: Polyethylene piping is corrosion-resistant, flexible, and
approved for underground fuel-oil installations.
- How often must aboveground fuel-oil storage tanks be inspected
according to FDNY regulations?
a) Every month
b) Every 6 months
c) Annually
d) Every 5 years
c) Annually
Rationale: FDNY requires annual inspections to ensure tanks are in
safe condition, free from leaks or corrosion.
- What is the minimum clearance required between an aboveground
- 1 foot
- 5 feet
- 10 feet 2 / 4
fuel-oil tank and a building?
- 15 feet
- 5 feet
Rationale: A minimum clearance of 5 feet helps prevent fire hazards
and allows access for maintenance.
- What device is required on all oil tanks to prevent overfilling?
a) Pressure gauge
b) Automatic shutoff valve
c) Sight gauge
d) Relief valve
b) Automatic shutoff valve
Rationale: Automatic shutoff valves prevent spillage and overfilling,
which could lead to fire hazards or environmental contamination.
- Which of the following is an approved method to detect leaks in
underground fuel-oil piping?
a) Visual inspection only
b) Hydrostatic testing
c) Pressure testing with nitrogen
d) Both b and c
d) Both b and c
Rationale: FDNY approves hydrostatic and pressure testing with inert
gases to detect leaks safely without risk of fire.
- What is the maximum capacity allowed for a residential aboveground
fuel-oil storage tank without requiring special permits? 3 / 4
- 250 gallons
- 500 gallons
- 1,000 gallons
- 2,000 gallons
- 500 gallons
Rationale: Residential tanks up to 500 gallons generally do not
require special FDNY permits but must comply with installation codes.
- Which type of venting is required for fuel-oil tanks?
a) Closed vent
b) Open vent
c) Pressure relief vent
d) No venting required
b) Open vent
Rationale: Open venting prevents pressure buildup and allows safe
filling and withdrawal of fuel.
- How far must a fuel-oil tank be from a property line?
- 2 feet
- 5 feet
- 10 feet
- 15 feet
- 10 feet
- / 4