FDNY S87 Certificate of Fitness for Professional Certification of the Installation of Fire Alarm Systems Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- Which agency regulates the installation of fire alarm systems in New
York City?
A. OSHA
B. NFPA
C. FDNY
- UL
Rationale: FDNY is the authority having jurisdiction (AHJ) in NYC and
regulates fire alarm installations.
2. The minimum height for mounting a manual pull station is:
- 36 inches
- 42 inches 1 / 4
- 48 inches
- 54 inches
Rationale: FDNY requires manual pull stations to be mounted at 42
inches from the finished floor to the center of the device.
- Which type of fire alarm system is designed to notify occupants but
- Proprietary
- Local
- Central station
- Remote station
does not alert the fire department automatically?
Rationale: Local fire alarm systems only alert occupants on-site,
without automatic off-site notification.
- What is the primary purpose of a fire alarm control panel?
- Sound the horns
- Monitor sprinklers
- Receive and process signals from initiating devices
- Display evacuation routes
Rationale: The fire alarm control panel processes signals from
detectors and initiates alarms.
- According to FDNY, what is the maximum spacing for smoke detectors
- 15 feet
- 30 feet 2 / 4
in a corridor?
- 50 feet
- 60 feet
Rationale: NFPA 72 and FDNY guidelines specify 30 feet maximum
spacing in corridors.
- Which type of detector is activated by visible or infrared light emitted
- Smoke detector
- Heat detector
- Flame detector
- Carbon monoxide detector
by a flame?
Rationale: Flame detectors respond to light energy from flames, not
smoke or heat.
- What color are fire alarm system wiring conductors typically?
- Black and white
- Red and black
- Red
- Green
Rationale: FDNY requires fire alarm wiring to be red for
identification.
- How often must a fire alarm system be tested according to FDNY
- Weekly
- Annually 3 / 4
regulations?
- Every 2 years
- Every 5 years
Rationale: Annual inspection and testing ensure proper system
operation.
- Which type of fire alarm system signals both the occupants and a
- Local
- Proprietary
- Central station
- Auxiliary
central monitoring station?
Rationale: Central station systems notify a monitoring center in
addition to occupants.
- What NFPA standard covers the installation of fire alarm
systems?
A. NFPA 13
B. NFPA 72
C. NFPA 101
D. NFPA 70
Rationale: NFPA 72 is the National Fire Alarm and Signaling Code
governing system installation and maintenance.
- Which device detects smoke particles suspended in the air?
- Heat detector
- Smoke detector