FDNY S18 Dry Chemical Fire Extinguishing Systems Inspection, Testing, and Servicing Technician (Citywide) Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf

  • A dry chemical system is primarily designed to suppress which type of
  • fire?

  • Class A
  • Class B
  • Class C
  • Class D

Rationale: Dry chemical systems are optimized for flammable liquid (Class

  • hazards.
  • What is the main extinguishing agent in a BC dry chemical system? 1 / 4
  • Water mist
  • Sodium bicarbonate
  • Potassium carbonate
  • Ammonium phosphate

Rationale: BC systems commonly use sodium bicarbonate for B and C

hazards.

  • Which document establishes maintenance requirements for dry
  • chemical systems?

A. OSHA 1910

B. NFPA 17

C. NFPA 25

D. NFPA 96

Rationale: NFPA 17 governs dry chemical extinguishing systems.

  • What is the minimum required frequency for a full system inspection?
  • Monthly
  • Quarterly
  • Semi-annually
  • Annually

Rationale: NFPA 17 requires semiannual inspections.

  • What device actuates the system automatically when heat is detected?
  • Manual pull
  • Annunciator 2 / 4
  • Fusible link
  • Alarm horn

Rationale: Fusible links melt at set temperatures, triggering actuation.

  • What is the purpose of a pressure gauge on a dry chemical cylinder?
  • Alarm testing
  • Monitoring propellant pressure
  • Flow verification
  • Agent purity testing

Rationale: Gauges indicate adequate nitrogen pressure for discharge.

  • Which test verifies unobstructed flow in the piping?
  • Pressure test
  • Valve test
  • Piping blowout test
  • Continuity test

Rationale: A blowout test ensures piping is free of blockages.

  • What must be replaced during semiannual maintenance?
  • System piping
  • Nozzles
  • Fusible links
  • Cylinders

Rationale: Fusible links are required to be replaced every six months.

  • What condition requires cylinder hydrostatic testing? 3 / 4
  • Every year
  • Every 3 years
  • Every 12 years
  • Never

Rationale: NFPA and DOT require 12-year hydrostatic testing for cylinders.

  • What is used to pressurize a dry chemical cylinder?

A. CO₂

  • Compressed air
  • Nitrogen
  • Argon

Rationale: Nitrogen is the standard inert pressurizing gas.

  • In a dry chemical kitchen system, what must shut down upon system
  • discharge?

  • Dishwasher
  • Fuel supply
  • Lighting
  • Ventilation supply only

Rationale: Automatic fuel shutoff is mandatory for fire suppression.

12. The discharge piping shall be inspected to verify:

  • Color coding
  • Proper support and no corrosion
  • Water flow
  • / 4

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

I was amazed by the in-depth analysis in this document. It was a perfect resource for my project. Truly remarkable!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 3, 2026
Description:

FDNY S18 Dry Chemical Fire Extinguishing Systems Inspection, Testing, and Servicing Technician (Citywide) Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | I...

Unlock Now
$ 1.00