FDNY S98 Fire Alarm Systems Inspection, Testing and Service Technician (Citywide) Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the primary purpose of a fire alarm system?
- To extinguish fires automatically
- To alert occupants and the fire department of a fire
- To inspect building electrical systems
- To prevent smoke from spreading
Rationale: Fire alarm systems are designed to provide early warning
to occupants and notify emergency services.
- Which NFPA standard governs the installation of fire alarm systems?
A) NFPA 10
B) NFPA 72
C) NFPA 72 1 / 4
D) NFPA 13
Rationale: NFPA 72 is the National Fire Alarm and Signaling Code,
providing requirements for installation, testing, and maintenance of fire alarm systems.
- What does “SLC” stand for in a fire alarm system?
- Signal Line Circuit
- Signaling Line Circuit
- Supervisory Loop Connection
- Standard Line Control
Rationale: SLC refers to the Signaling Line Circuit used to connect
intelligent devices to the fire alarm control panel.
- Which device is a heat detector?
- Smoke detector
- Pull station
- Fixed temperature detector
- Horn/strobe
Rationale: Heat detectors respond to temperature changes and can
be either fixed temperature or rate-of-rise types.
- How often must smoke detectors in commercial buildings be tested
- Monthly
- Weekly
- Annually 2 / 4
according to NFPA?
- Every 5 years
Rationale: NFPA requires annual testing of smoke detectors, with
periodic functional checks as defined by the manufacturer.
- What is the function of a fire alarm control panel (FACP)?
- To supply water to sprinklers
- To monitor inputs from detection devices and control outputs
- To detect fire directly
- To inspect fire extinguishers
Rationale: The FACP monitors detection devices, processes signals,
and initiates alarms or notifications.
7. A “trouble” signal on a fire alarm panel indicates:
- Fire in progress
- A system malfunction or fault
- Normal operation
- Battery replacement needed only
Rationale: Trouble signals notify that a component or circuit is not
functioning correctly, requiring maintenance.
- Which type of fire alarm notification appliance is visible?
- Horn
- Bell
- Strobe
- Pull station 3 / 4
Rationale: Strobes provide visual alert for hearing-impaired
occupants.
- What is a supervisory signal?
- Alarm for fire
- Indicates an abnormal condition in a system requiring attention
- Pull station activation
- Malfunction of smoke detectors
Rationale: Supervisory signals indicate conditions like valve closures
or power loss in life-safety systems.
- How should batteries in a fire alarm system be tested?
- By opening them
- By disconnecting the system
- Using a load test according to manufacturer instructions
- By measuring voltage only
Rationale: Load testing ensures the battery can supply power under
actual operating conditions, not just voltage presence.
- Which device initiates an alarm manually?
- Smoke detector
- Heat detector
- Manual pull station
- Horn/strobe
Rationale: Manual pull stations allow building occupants to activate
the alarm manually.
- / 4